User`s guide
20 007-5474-003
1: SGI Altix XE Cluster Quick-reference
Serial Access to the SMC Switch
Use of a serial interface to the switch should only be needed if the factory assigned IP address for
the switch has been somehow deleted, altered or corrupted. Otherwise, use of the web or telnet
access procedure is recommended. To use a serial interface with the switch, connect a laptop, or
PC to the switch’s console port. Refer to
Figure 1-9 for the location of the console port and use the
steps that follow for access.
1
2
3
4
5
6
7
8910
11
12
13
14
15
16
17
18 19 20
21 22
23
24
37
38
39
40
41
42 43 44
45 46
47
48
25
26
27
28
29
30 31 32
33 34
35
36
Master
Select
Stack ID
45 46
47
48
Console
Pwr
RPS
Diag
Stack Master
TigerStack II
10/100/1000
8848M
Module
Stack Link
S
MC8848M
Port status LEDs
10/100/1000 Mbps RJ-45 ports
Stack ID Console port
System indicators SFP slots
Figure 1-9 SMC Switch Connectors Example
1. Establish a command line interface (CLI) and list the port connection settings:
Port Settings
Bits Per Second=19200
Data bits=8
Parity=None
Stop Bits=1
Flow Control=none
2. In order to verify and save any new settings type the following:
console# show running-config (make sure your settings are intact)
console# copy running-config startup-config (it will ask for a file name)
console# file name? startup
Note: Any changes made to the switch port settings through the serial interface or Web
interface are not saved unless the previous steps have been executed.
3. Power cycle the switch by disconnecting and reconnecting its power cable.