XE210 User’s Guide
Installing the Heat Sink(s)
To install a heat sink, use the following instructions:
1. Ensure that you have replaced the heat sink’s TIM. See the preceding section
“Replacing Thermal Interface Material”.
2. Set the heat sink over the processor, lining up the four captive screws with the four
posts surrounding the processor.
3. Loosely screw in the captive screws on the heat sink corners in a diagonal manner.
Do not fully tighten one screw before tightening another.
4. Gradually and equally tighten each captive screw until each is firmly tightened.
Figure 27. Installing the Heat Sink (2U Passive Heat Sink Shown)
5. Reinstall and reconnect any parts you removed or disconnected to reach the
processor sockets.
6. Replace the server's cover and reconnect the AC power cord(s). See “Removing
and Installing the System Cover” for instructions on installing the server's cover.
TP02077