User`s guide
Emergency Management Port (EMP) Console
89
The following information displays if the -v option is included in the command line.
The /D FRU command may be followed with up to 16 device addresses. These device
addresses are used to view up to 16 different FRU areas, instead of the default of
displayingthe BMC FRU.Theargumentsfollowingthe-d FRU areinthe same orderand
valueas the NVS_TYPE,NVS_LUN, DEV_BUS and DEV_ADDRESS which arefound in theFRU
file header in each FRU file. The LUN address is optional. If the LUN address is used, it
must start with an L.
Usage: FRUSDR -d fru (device) [lun] (bus) (addr) (addr2) (etc)
Example: FRUSDR /D FRU IMBDEVICE L00 00 C0 C2
The configuration file may be used to load multiple FRU and SDR files. In the
configuration file, you may define which FRU and SDR areas are to be programmed.
Additionally,you may requestinformation fromtheuserorasktheusertochoosewhich
areas to program.
Displaying a Given Area
When the utility is run with the -d DMI, -d FRU, or -d SDR command line flag, the
indicatedareaisdisplayed.Eacharearepresentsonesensorforeachinstrumenteddevice
in the server. If the given display function fails because of an inability to parse the data
present or a hardware failure, the utility displays an error message and exits.
Displaying DMI Area
Each DMI area displayed is headed with the DMI area designated name. In each area,
each field has a field name header followed by the field in ASCII or as a number.
Example:
To display the DMI area, type frusdr -d dmi and press Enter.