Installation manual
39
10-35 “A” - “Z”
36-61 “a” - “z”
62 and greater “?”
NOTE: The DRL2A will not respond to any interactive
commands from the ITI panels. The audio feature is
supported for ITI accounts.
Video Downlook Protocol:
DRRLssssssAAAAGCsVPa[DC4]
Where, D : Protocol number
RR : Receiver number
L : Line number
ssssss : Spaces
AAAA : Account code
G : Line Test Grade 1-9, 0=Bypassed
A-Z=Text to follow, up to 6
characters
C : Control code 1-F, which is the first
digit of alarm code from 4/3 format
or 4/2 format
s : Space
V : Camera number 1-F, 0=No,
X=Unknown
P : Picture number 1-8, 0=No
a : Audio Indicator, 1=Audio, 0=No
Audio
[DC4] : Terminator, 14 Hex
SIA Video Downlook Protocol
DRL2A v2.1i supports the SIA video block (available on the
DSC PC1580, DSC PC5010 and DSC PC5015). In order to
ensure proper decoding, options [31] (SIA option) and [4E]
(Downlook option) must be enabled. The video signal will
be sent to the computer as follows:
SRRL[#AAAA|pt010/cn00x/im00x][DC4]
Where, S : SIA header
RR : Receiver number
L : Line number
AAAA : Account code
| : Field separator
pt : Manufacturer identifier (010 for
DSC/Sur-Gard)
/ : Data code packet separator
cn : Camera number
im : number of images (3 digits)
[DC4] : Terminator, 14 hex
SIA AIR Downlook Protocol:
SRRL[#AAAA|lpt010/ad004/cn00x][DC4]
Where, S : SIA header
RR : Receiver number
L : Line number
AAAA : Account code
| : Field separator
l : Video block function code
pt : Manufacturer identifier (010 for
DSC/Sur-Gard)
/ : Data code packet separator
ad : Additional images (fixed to 004)
cn : Camera number
[DC4] : Terminator, 14 hex
FBI Protocol
JRRLssssssAAAATZZEss[DC4]
Where, J : FBI protocol identifier
RR : receiver number
L : Line number
s : spaces
AAAA : Account code.
T : Zone type
ZZ : Zone number, in hex.
E : Event code
if E=0 and T=0 : listen in.
Robofon Protocol
HRRLssssAAAAAAsEssYZ[DC4]
Where, H : Robofon protocol identifier
RR : Receiver number
L : Line number
s : Spaces
AAAAAA : account code
E : event code
YZ : reporting code
[DC4] : terminator string from receiver
Scancom 433 Protocol
1RRLssssssAAAAsEssZZT
Where, AAAA : account code
E : event code
When (protocol 1) E=A: alarm
E=B: bypass
E=H: maintenance restoral
E=C: close
E=K: keypad
E=O: open
E=R: restore
E=T: trouble
ZZ : zone number
T : terminator character
or
KRRLssssAAAAEEEZZZFFT (option 60=01)
Where, K : protocol identifier
RR : receiver number
L : line number
s : spaces
AAAA : account code
EEE : event type
Event Type Code
Status 0EF
Restore 034
Test cancel 0BC
Bypass 056
Trouble 078
Opening 996
Closing 995
Duress 00F
Emergency 1 00B
Emergency 2 00C
Emergency 3 00D
Emergency 4 00E
ZZZ : zone number
Zone Code Zone Code
1 011 9 021
2 012 10 022