Installation manual

24
FBI Super Fast Format
This DTMF format consists of 4-digit Account Codes, 2-digit zone codes, 1-digit zone type codes, and 1-digit event codes.
The zone codes will be converted into 3-digit decimal codes by the DRL2A.
The following are the zone type codes used by this format:
ITI Format
The ITI format covers ITI panel models: RF Commander, Caretaker plus, SX-V, Commander III, Commander 2000 and
Security Pro 5000. In order to receive the ITI format, handshake #10 must be programmed. After a coldboot, the fifth
handshake (option [45]) is programmed as 10.
ITI Library
Sensor No. Printed out as Specifics
00 00 Buddy Alarm xx SX-V only
01-32 xx ALM Caretaker plus
00-16 xx ALM RF Commander / Commander III
02-07 xx ALM SX-IVB
01 Bad sensor #xx SX-V only
02-76 xx ALM SX-V
01-18 xx ALM Commander 2000
01-76 xx ALM Ultraguard 5000
77 77 Alarm Tmpr / Supervisory / CANC Caretaker plus, SX-IVB, SX-V, Ultraguard 5000 only
78 78 TRB Caretaker plus, Utraguard 5000 only
79 79 No activ alm / CANC Caretaker plus, Ultraguard 5000 only
80 80 Alarm All supported ITI panels
81 81 Alarm All supported ITI panels
82 82 Alarm All supported ITI panels
83 83 Phone Tst All supported ITI panels
84 84 OpenUsr xx All supported ITI panels
85 85 CloseUsr xx All supported ITI panels
86 86 SilentDuress All supported ITI panels
87 87 ForceArmed / AutoForceArm All supported ITI panels
88 88 TRB Caretaker plus, Ultraguard 5000 only
89 89 TRB Caretaker plus, Ultraguard 5000 only
90 90 AC Fail / RESTR All supported ITI panels
91 91 Low CPU Bat / RESTR All supported ITI panels
92 92 AlmTamprLoop / RESTR All supported ITI panels
93 93 AutoPhoneTst All supported ITI panels
94 94 TRB All supported ITI panels
95 95 CPU Back In / 95 RESET All supported ITI panels
96 Failure to communicate Local alarm only
97 No phone line Local alarm only
98 98 Event Dump Report Commander 2000 only
FBIFBI
FBIFBI
FBI
CodeCode
CodeCode
Code
Converted Event CodeConverted Event Code
Converted Event CodeConverted Event Code
Converted Event Code
EventEvent
EventEvent
Event
Nine 9 A
Zero 0 A
Opening B O
Closing C C
Abort D T
Restore E R
Trouble F T
Note that option [3B] can give a unique FBI RS232 output
when enabled.
BFSK Format
The printer messages will be similar to the following:
L01-123-CLOSING ID1 15:19:23-10/06
• L01 represents Line 01
• 1234 represents the account codes.
The Signals will be sent to the computer as
6011ssssssAAAAXXYYYY[DC4]
Following the example described above, the signal will be
sent to the computer as:
6011ssssss1234sAs300[DC4]
FBIFBI
FBIFBI
FBI
CodeCode
CodeCode
Code
Converted Event CodeConverted Event Code
Converted Event CodeConverted Event Code
Converted Event Code
EventEvent
EventEvent
Event
Fire 1 A
Panic 2 A
Burglary 3 A
Medical 4 A
Auxiliary 5 A
Bypass 6 B
Inactive 7 A
Eight 8 A