5.3 Backup Current Line Card Configuration: LC-
FE-03-03
When the Line Card has been configured, the programming
changes can be recorded as a “back up” program. The
“back up” configuration may be later used to restore the
Line Card’s configuration after temporary changes are made.
To store the present Line Card configuration, enter the LC-
FE-03-03 command.
5.4: Install Backup Configuration as Current Line
Card Configuration: LC-FE-04-04
If the Line Card configuration is temporarily changed (for
example, to overcome a temporary problem or for
experimentation), the configuration stored using the LC-
FA-03-03 command may be restored.
To restore the “back up” configuration, enter the LC-FE-04-
04 command.
DRL2A Communication Formats
Common Formats
The following formats are commonly used:
• 3/1, 4/1, 4/2 formats; 10, 14, 20 baud
• 3/1 extended format; 10, 14, 20, 40 baud.
3/1, 4/2 formats with or without Checksum; 40 baud
3-2 format; 10, 14, 20 baud (option)
4/1 Extended format; 10, 14, 20 baud (option)
4/2 Extended format; 10, 14, 20, 40 baud (option)
Sur-Gard DTMF Formats
Sur-Gard DTMF 4/3 and 4/3 with Checksum formats provide
fast, reliable and easy to understand and decode data
transmission. On-line time will be greatly reduced when
using 4/3 and 4/3 with Checksum formats. The 4/1 and 4/
2 DTMF formats can also be decoded by the DRL2A.
The 4/3 with Checksum format is recommended for use
with Sur-Gard and DSC security control panels.
Ademco Contact ID Format
This DTMF format requires a dual tone handshake and
1400 Hz kissoff, or 1400Hz handshake and 1400Hz kissoff.
NOTE:NOTE:
NOTE:NOTE:
NOTE: If the dialer responds to a 2300 Hz handshake by
sending the Contact ID Format data, the DRL2A will accept
and decode the format. The DRL2A will send a 1400Hz
kissoff tone regardless of the handshake.
The DRL2A will display a message similar to this one:
L01-1234 E130L01-1234 E130
L01-1234 E130L01-1234 E130
L01-1234 E130
01 C025*01 C025*
01 C025*01 C025*
01 C025*
Access Control - 420Access Control - 420
Access Control - 420Access Control - 420
Access Control - 420
421 Access denied
422 Access report by user
System Disables - 500 and 510System Disables - 500 and 510
System Disables - 500 and 510System Disables - 500 and 510
System Disables - 500 and 510
Sounder/Relay disables - 520Sounder/Relay disables - 520
Sounder/Relay disables - 520Sounder/Relay disables - 520
Sounder/Relay disables - 520
520 Sounder/Relay disabl
521 Bell 1 disable
522 Bell 2 disable
523 Alarm relay disable
524 Trouble relay disable
525 Reversing relay disable
System peripheral Disables - 530System peripheral Disables - 530
System peripheral Disables - 530System peripheral Disables - 530
System peripheral Disables - 530
and 540and 540
and 540and 540
and 540
Communication Disables - 550Communication Disables - 550
Communication Disables - 550Communication Disables - 550
Communication Disables - 550
and 560and 560
and 560and 560
and 560
551 Dialer disabled
552 Radio xmitter disabled
Bypasses - 570Bypasses - 570
Bypasses - 570Bypasses - 570
Bypasses - 570
570 Zone bypass
571 Fire bypass
572 24 Hour zone bypass
573 Burg. bypass
574 Group bypass
Test/Misc. - 600Test/Misc. - 600
Test/Misc. - 600Test/Misc. - 600
Test/Misc. - 600
601 Manual trigger test
602 Periodic test report
603 Periodic RF Xmission
604 Fire test
605 Status report to follow
606 Listen-in to follow
607 Walk Test Mode
621 Event log reset
622 Event log 50% full
623 Event log 90% full
624 Event log overflow
625 Time/Date Reset
626 Time/Date inaccurate
627 Program mode Entry
628 Program mode Exit
631 Exception Schedule change
153 Loss of heat
154 Water leakage
155 Foil break
156 Day trouble
157 Low bottled gas level
158 High temp
159 Low temp
161 Loss of air flow
Fire supervisory - 200 and 210Fire supervisory - 200 and 210
Fire supervisory - 200 and 210Fire supervisory - 200 and 210
Fire supervisory - 200 and 210
200 Fire supervisory
201 Low water pressure
202 Low CO2
203 Gate valve sensor
204 Low water level
205 Pump activated
206 Pump failure
System Troubles - 300 and 310System Troubles - 300 and 310
System Troubles - 300 and 310System Troubles - 300 and 310
System Troubles - 300 and 310
300 System trouble
301 AC loss
302 Low system battery
303 RAM checksum bad
304 ROM checksum bad
305 System reset
306 Panel program changed
307 Self-test failure
308 System shutdown
309 Battery test failure
310 Ground fault
Sounder/Relay Troubles - 320Sounder/Relay Troubles - 320
Sounder/Relay Troubles - 320Sounder/Relay Troubles - 320
Sounder/Relay Troubles - 320
320 Sounder/relay
321 Bell 1
322 Bell 2
323 Alarm relay
324 Trouble relay
325 Reversing
System Peripheral Troubles - 330System Peripheral Troubles - 330
System Peripheral Troubles - 330System Peripheral Troubles - 330
System Peripheral Troubles - 330
and 340and 340
and 340and 340
and 340
330 System Peripheral
331 Polling loop open
332 Polling loop short
333 Exp. module failure
EVENT CODES CLASSIFICATIONEVENT CODES CLASSIFICATION
EVENT CODES CLASSIFICATIONEVENT CODES CLASSIFICATION
EVENT CODES CLASSIFICATION
The Event codes have been grouped according to the type of event, as described below.
Medical Alarms - 100Medical Alarms - 100
Medical Alarms - 100Medical Alarms - 100
Medical Alarms - 100
100 Medical
101 Pendant transmitter
102 Fail to report in
Fire Alarms - 110Fire Alarms - 110
Fire Alarms - 110Fire Alarms - 110
Fire Alarms - 110
110 Fire alarm
111 Smoke
112 Combustion
113 Water Flow
114 Heat
115 Pull Station
116 Duct
117 Flame
118 Near alarm
Panic Alarms - 120Panic Alarms - 120
Panic Alarms - 120Panic Alarms - 120
Panic Alarms - 120
120 Panic alarm
121 Duress
122 Silent
123 Audible
Burglar Alarms - 130Burglar Alarms - 130
Burglar Alarms - 130Burglar Alarms - 130
Burglar Alarms - 130
130 Burglary
131 Perimeter
132 Interior
133 24 Hour
134 Entry/Exit
135 Day/Night
136 Outdoor
137 Tamper
138 Near alarm
General alarmsGeneral alarms
General alarmsGeneral alarms
General alarms
140 General alarm
141 Polling loop open
142 Polling loop short
143 Expansion module failure
144 Sensor tamper
145 Expansion module tamper
24 Hour Non-Burglary - 150 and24 Hour Non-Burglary - 150 and
24 Hour Non-Burglary - 150 and24 Hour Non-Burglary - 150 and
24 Hour Non-Burglary - 150 and
160160
160160
160
150 24 Hour non-burg
151 Gas detected
152 Refrigeration
334 Repeater failure
335 Local printer paper out
336 Local printer failure
Communication Troubles - 350Communication Troubles - 350
Communication Troubles - 350Communication Troubles - 350
Communication Troubles - 350
and 360and 360
and 360and 360
and 360
350 Communication
351 Telco 1 fault
352 Telco 2 fault
353 Long range radio
354 Fail to communicate
355 Loss of radio supervision
356 Loss of central polling
Protection Loop Troubles - 370Protection Loop Troubles - 370
Protection Loop Troubles - 370Protection Loop Troubles - 370
Protection Loop Troubles - 370
370 Protection loop
371 Protection loop open
372 Protection loop short
373 Fire trouble
Sensor Troubles- 380Sensor Troubles- 380
Sensor Troubles- 380Sensor Troubles- 380
Sensor Troubles- 380
380 Sensor trouble
381 Loss of super. - RF
382 Loss of super. - RPM
383 Sensor tamper
384 RF xmtr. low battery
Open/close - 400Open/close - 400
Open/close - 400Open/close - 400
Open/close - 400
400 Open/Close
401 O/C by user
402 Group O/C
403 Automatic O/C
404 Late to O/C
405 Deferred O/C
406 Cancel
407 Remote arm/disarm
408 Quick Arm
409 Keyswitch O/C
Remote Access - 410Remote Access - 410
Remote Access - 410Remote Access - 410
Remote Access - 410
411 Callback request made
412 Succes - download access
413 Unsuccessful access
414 System shutdown
415 Dialer shutdown