Specifications

27
E6zz Expand trouble station ID zz (zz=17-31)
EEzz Expand restore station ID zz (zz=17-31)
E100 Automatic test
E2zz Manual test zone ZZ
F000 Automatic closing
F400 Automatic opening
F1zz : Normal closing ID ZZ
F5zz : Normal opening ID ZZ
F2zz : Forced closing ID ZZ
F6zz : Forced opening ID ZZ
F3zz : Supervised closing ID ZZ
F7zz : Supervised opening ZZ
FD0a : Closing area 0a
FF0a : Opening area 0a
F8zz : Access
F9zz : Access left open ID zz
FAzz : Access forced ID ZZ
FBzz : Access station ID ZZ
FC00 : Duress
FE00 : Data lost
7.14 SESCOA SUPER SPEED
Sescoa Super Speed is a 40 Baud communication for-
mat. Account codes are programmed as 4-digit deci-
mal codes ranging from 0001 to 3374. The account
code is followed by a 1-digit event code, a 2-digit
alarm code, and 1-digit checksum.
Option [A5] must be programmed as “01” in order to
use Sescoa Super Speed decoding instead of 4/2 with
checksum decoding.
Example:
Printer: L01-1234—LOW BATT HH:MM:SS-DD/MM
Computer: 7017ssssss1234sF
7.15 DRL2E Predefined Library Decoding and
Event Codes Table
7.15.1 3/1 - 4/1 Alarm Library
7.15.2 3/1-4/1 Extended, 3/2 & 4/2 Alarm Library
7.15.3 4/2 Extended & 4/3 Alarm Library
Ensure that the central station automation software is able
to accept these codes if they are to be used.
7.15.4 Event Codes Summary
Code Event
0 Automatic Test
1Fire Alarm
2Panic Alarm
3 Burglary Alarm
4 Closing by User Number
5 Opening by User Number
6 Service
7 Medical Emergency
8 Message
9 Restore
AAlarm
BBypass
CClosing
D or / Cancel
H Unbypass
O Opening
R Restore
TTrouble
Z Common Event Code
20 Hex Common Event code “Space”
For Alarm
Message
Corresponding
Code
Event
Code (Options 30-3F)
0 (A) A
PER TEST REPORT
1 A FIRE ALARM
2 A PANIC ALARM
3ABURGLARY
4 A GENERAL ALARM
5 A GENERAL ALARM
6 A GENERAL ALARM
7 A MEDICAL
8 A SYSTEM TROUBLE
Restore 9 R RESTORE
Open B O OPENING
CloseCCCLOSING
Cancel D / CANCEL
Restore E R RESTORE
Trouble F T SYSTEM TROUBLE
Alarm 0x (Ax) A
PER TEST REPORT
Alarm 1x A FIRE ALARM
Alarm
2x A PANIC ALARM
Alarm
3x A BURGLARY
Alarm 4x A GENERAL ALARM
Alarm 5x A GENERAL ALARM
Alarm 6x A GENERAL ALARM
Alarm 7x A MEDICAL
Alarm 8x A SYSTEM TROUBLE
Restr 9x R RESOTRE
Open Bx O OPENING
Close Cx C CLOSING
Cancl Dx / CANCEL
Restr Ex R RESTORE
Trble Fx T SYSTEM TROUBLE
Alarm 0xx(Axx) T 0
PER TEST REPORT
Alarm 1xx A 1 FIRE ALARM
Alarm
2xx A 2 PANIC ALARM
Alarm
3xx A 3 BURGLARY
Close 4xx C 4 CLOSING
Open 5xx O 5 OPENING
Alarm 6xx T 6 SERVICE
Alarm 7xx A 7 MEDICAL
Alarm 8xx A 8 MESSAGE
Restr 9xx R 9 RESTORE
CloseGrp Bxx C C OPENING
OpenGrp Cxx O O CLOSING
Bypas Dxx BBCANCEL
Unbyp Exx H H RESTORE
Cancl Fxx / / SYSTEM TROUBLE