Camera Configuration
Each camera’s parameters can be defined in this section. Select a channel that you’d like to configure.
Set the information of the camera.
• Camera Name: Enter the name of the channel in up to 21 alphanumeric or up to 10 Unicode
characters.
• Image Size: Select the resolution of each channel’s video data. This attribute applies to all the
channels. (You may set the Image Size to what you did in IP Devices Registration.)
• Image Quality
In Image quality level setup, selecting the left results in higher image quality, but requires higher
network bandwidth. Selecting the right requires lower network bandwidth, but gives degraded image
quality.
After finishing the setting, click Apply button to save the changes. If you default button, every fields
will be filled with the default values.
5.3.6. Built-in Camera Control for FW1130/1131/1132/1173/1175
With this feature, you can send control signals to a camera when it supports functions such as AGC,
ELC, AWB, etc. The OSD control window has four buttons of Up, Down, Left, Right, and Enter
button.
On the center is the Enter button, and when it’s pressed it goes to Menu Mode so that you can see
the status of the menu. Moving on the menu items is done by Up and Down buttons, and the value
change is done by Left and Right buttons.
SETUP Menu
Function Description
LENS MANUAL / DC / VIDEO IRIS Control type of the lens mounted
SHUTTER ESC / MANUAL / FLK MANUAL : 1/60(50) - 1/120,000 sec, x2 - x128
WHITE BAL. ATW / AWC / MANUAL
ATW: 1,800 10,500°K *AWC: ONE PUSH
MANUAL: Adjustable between Red and Blue.
BACKLIGHT OFF / LOW / MIDDLE / HIGH
Backlight compensation
AGC OFF / LOW / MIDDLE / HIGH
Brightness can be adjusted.(1 - 70)
DNR OFF / LOW / MIDDLE / HIGH
DNR is not functional if AGC is OFF.
SENS-UP OFF / AUTO SENS-UP is not functional if AGC is OFF.
SPECIAL (* Refer to the table below) -
Low Compression Highest