User`s manual
FlexWATCH User Manual Part 3
4029 29 INTPLUS
1. Local IP Address will be assigned to FlexWATCH® and Remote IP Address will be assigned
to the other party’s device. Therefore, if Client PC makes a call to FlexWATCH®,
FlexWATCH® gets the Local IP Address whereas Client PC gets the Remote IP Address.
Local IP address:
System default IP address (192.168.2.1) resides in the FlexWATCH® server for modem connection
only. So when you connect the FlexWATCH® server from remote PC using dial-up networking and physical
connection is made, you need to run your web browser and enter this system default IP address
(192.168.2.1) to view live video. You can change this system default IP address as well. But it is
recommended not to change system default IP address for modem connection to prevent any possible error.
Remote IP address:
IP address which is automatically given to remote client PC by FlexWATCH® server when
FlexWATCH® server is connected by remote client PC using dial-up networking. This IP address
(192.168.2.2) is for data communication between FlexWATCH® server and Remote client PC. So you do
not need to change this IP address. But if you change default IP address of FlexWATCH® server
(192.168.2.1) for modem connection to different class of IP address, you need to change remote IP address
to the same class of IP to match the IP class.
Notice) Note that when Local IP address is change, remote IP address should be changed into the
same class of the IP address.
2. You can select Authentication Mode among PAP, CHAP, or None
PAP Connection is made by User ID & Password registered below sections.
CHAP With User ID, Password, it applies another encryption method for higher security.
NONE Do not use authentication mode.
3. In order to use PAP or CHAP authentication mode you need to register at least one user. You
can register up to 3 users for this service.