FlexWATCH User Manual Part 3
4029 23 INTPLUS
5. NVCP Port field will be activated only when Connection Type is “Active (Static IP)”. NVCP
Port (Destination Rx Port) should be the same as the service port number of Rx Module of
NVR. Default value is 50100 and the value can be up to 65535. NVCP port field will only be
activated when Connection Type is Active (Static IP).
6. VS Module ID is the number of the built-in module of NVS or NCS, which provides remote
channels. VS Module ID is always 0(default value) for any 1, 2, or 4 channel server. If you
select any other number, it won’t work properly.
7. If you want change NVCP Password instead of default password “nvcp”, please enter new
password in New Password and Confirm Password fields.
8. After the configuration is done, please click Save, otherwise please click Back button.
9. After Tx Module change, please click “Apply” button so that the new configuration can take
effect.