FW3150 User’s Manual Part 1
4031 1 INTPLUS
2. Hardware Description
2.1. FW-3150 Front Panel View
Picture 2 : FW-3150 Front Panel
A B C D E F G
Name Description
A Power
Power input ports for DC 12V 0.8A [SMPS].
Use the original power supply unit from the package.
B Grounding Connector Grounding Connector
C
Factory Default
Button
This button can reset the factory default settings at the system.
especially when a user lost his/her admin-password, or when it got
any uncertain faulty operation.
- After reboot the system, wait until hearing two times of beep sound.
- Keep pressing FD button for 5~10 seconds until hearing three times
short beep sound. ACT LED blinks during the process. The system
will reboot automatically when it’s completed.
D LAN LAN Port for 10/100M Base T Auto sensing.
E COM
RS-232 ports for Serial input device, Modem or
Console (Hyperterminal.connection).
F POWER LED Red light blinks when power is provided.
G LAN(Tx/Rx) LED
Green light blinks when there is data transmission on the connected
LAN.
Table 3 : FW-3150 Front Panel Description