8. Firmware Update
8.1 Firmware update process
1) Connect your PC and FlexWATCH server in the network.
2) Run FlexWATCH Installer and click Search. Select the FlexWATCH server you need to update the
firmware. If IP Setup is not made, assign a static IP address according to the steps in section ‘5.1 Static
IP Assignment, Manual or Auto Setup’.
3) Click “FlexWATCH Update” button.
4) A new folder will be automatically created under the location of FlexWATCH Installer files.
(C:\Program Files\FlexWATCH\FlexWATCH Installer)
For example, ‘FW-3440-A folder will be created if FW-3440-A model is selected.
5) Place the proper firmware files into the folder that has been created at step 4.
6) Input the correct password (root), and click ‘Start update’ button.
7) If the update process is completed, FlexWATCH server will be automatically rebooted.
8) Wait until the rebooting is done (2~4 min), and click ‘Get version’ button to check out the result.