4.7. Input/Output Setup [FW-1130 & FW-3150 Only]
4.7.1. Input / Output Type Configuration
z Please select Normal Open Type for normal open type sensor connected to DI. Normal Open
means that a switch normally is off and when an event is occurred the switch turns on.
z Please select Normal Close Type for normal close type sensor connected to DI. Normal
Close means that a switch normally is on and when an event is occurred the switch turns off.
z Please select Input Type in accordance with Sensor Type and select Output Type in
accordance with Alarm’s working type. Specially, if you physically don’t use DI, please
select Normal Open for Input Type.
4.8. Alarm Output Control [FW-3450 & FW-5450 Only]
FW-3450 & FW-5450 have 4 Alarm Outputs. If you select Enable for DO, it is arbeit contact; otherwise,
it is break contact.
4.9. Alarm Output Control [FW-1130 & FW-3150 Only]
FW-3150 has 1 alarm Output. If you select Enable for DO, it is arbeit contact; otherwise, it is break