Drive Technology \ Drive Automation \ System Integration \ Services Compact Operating Instructions Operator Panels DOP11C Edition 08/2013 20149344 / EN
SEW-EURODRIVE—Driving the world
Contents Contents 1 General information ............................................................................................ 5 1.1 Scope of this documentation....................................................................... 5 1.2 Design of the safety notes .......................................................................... 5 1.2.1 2 Meaning of signal words .............................................................. 5 1.2.2 Design of the section-related safety notes..........
Contents 4.4 Connecting a voltage supply..................................................................... 23 4.5 Connecting the operator panel.................................................................. 24 4.5.1 Preparation ................................................................................ 24 4.5.2 Connecting the operator panel to the frequency inverter and PC.............................................................................................. 25 4.5.3 5 6 Startup.
General information Scope of this documentation 1 General information 1.1 Scope of this documentation 1 This documentation comprises the general safety notes and selected information regarding DOP11C operator panel. • Please note that this documentation does not replace the detailed system manual (still in progress). • Please consult the online help of the project planning software HMI-Builder.PRO before using the operator panels DOP11C.
General information Right to claim under warranty 1 1.2.2 Design of the section-related safety notes Section-related safety notes do not apply to a specific action, but to several actions pertaining to one subject. The symbols used either indicate a general hazard or a specific hazard. This is the formal structure of a safety note for a specific section: SIGNAL WORD! Type and source of danger. Possible consequence(s) if disregarded. • 1.2.3 Measure(s) to prevent the danger.
General information Product names and trademarks 1 Always use the latest version of the documentation and software. The SEW-EURODRIVE homepage (www.sew-eurodrive.com) provides a wide selection of documentation in various languages available for download. If required, you can also order printed and bound copies of the documentation from SEW-EURODRIVE. 1.6 Product names and trademarks The product names mentioned in this documentation are brands or registered brands of the titleholders. 1.
Safety notes General information 2 2 Safety notes 2.1 General information 2.2 • Read the safety notes carefully. • Check the delivery for damage caused during transport on receipt. If damage is found, advise your supplier. • The panel meets the requirements of article 4 of the EMC Directive 2004/108/EC. • Do not use the operator panel in or near a mining facility or outdoors, or in areas where there is a risk of explosion or fire hazard.
Safety notes Designated use 2.3 2 Designated use The operator panel of the DOP11C series are intended for the operation and diagnostics of industrial and commercial systems. The DOP11C series comprises only panels for fixed installation . A suitable response to communication errors between the DOP11C and the controller must be implemented in the controller. Additionally, suitable measures (e.g.
Safety notes Preventive measures and protection devices 2 2.6 Preventive measures and protection devices Make sure that preventive measures and protection devices correspond to the applicable regulations (e.g. EN 60204 or EN 50178). 2.7 Required preventive measure: Grounding the unit Required protection devices: Overcurrent protection devices Transportation / storage Immediately upon delivery, inspect the shipment for any damage that may have occurred in transit.
Safety notes Operating notes 2.9 2.10 2.11 2 Operating notes • Always keep the panel clean. • Emergency stop and other functions should not be controlled from the operator panel. • Make sure that the keys, display, etc. are not touched by any sharp objects. • Bear in mind that the panel is ready for operation even if the backlighting is no longer illuminated, which means that entries made on the keyboard and touchscreen will still be registered.
Unit structure Type designation and nameplates 3 3 Unit structure 3.1 Type designation and nameplates 3.1.1 Sample type designation DOP 11 C 40 TFT-/LCD display Design Version C 40 = 4.3 inches, 480 x 272 pixels 65,536 colors 70 = 7 inches, 800 x 480 pixels 65,536 colors 100 = 10.4 inches, 640 x 480 pixels 65,536 colors 120 = 12.1 inches, 1280 x 800 pixels 262,144 colors 150 = 15.4 inches, 1280 x 800 pixels 262,144 colors Generation Type: DOP = Drive Operator Panel 3.1.
Unit structure Scope of delivery 3.
Unit structure DOP11C-40, -70 and -100 3 3.3 DOP11C-40, -70 and -100 The following sections will give you an overview of the display and the connections. For further details, refer to chapter "Technical data and dimension sheets". 3.3.
Unit structure DOP11C-40, -70 and -100 3.3.2 3 Connections • The following illustration shows the connections on the bottom of the operator panel: [1] [2] [3] [4] 8993407371 Pos.
Unit structure DOP11C-120 and -150 3 3.4 DOP11C-120 and -150 The following sections will give you an overview of the display and the connections. For further details, refer to chapter "Technical data and dimension sheets". 3.4.
Unit structure DOP11C-120 and -150 3.4.2 3 Connections • The following illustration shows the connections on the bottom of the operator panel: [1] [2] [3] [4] [5] [6] [7] 8993562379 Pos. Connection Description [1] Voltage supply DC 24 V (18 – 32 VDC) [2] COM1/2 Communication ports (serial, 9-pin D-sub) • RS232 • RS422 • RS485 [3] Ethernet interface (LAN2) 1 x 10/100/1000 Base-T (shielded RJ45) [4] USB interface 2 x USB host 2.0, max.
Installation Important installation notes 4 4 Installation 4.1 Important installation notes 4.1.1 Installation notes for the basic unit Separate cable ducts Route power cables and electronic cables in separate cable ducts. Cross-sections • Voltage supply: Cross section according to nominal input current. • Electronics cables: – 1 conductor per terminal 0.20 ... 0.75 mm2 (AWG 20 ... 17) – 2 conductors per terminal 0.20 ... 0.75 mm2 (AWG 20 ...
Installation Important installation notes 4.1.2 4 UL-compliant installation Note the following information for UL-compliant installation: • Use only copper conductors with a temperature range of 60 / 75 °C as connection cable. WARNING • • • Disconnect units only if no voltage is applied. This device is equipped with a battery. The unit must be used on an even surface with protection 4X. Only for indoor use.
Installation Important installation notes 4 4.1.3 Space required for installation The thickness of the mounting plate depends on the unit type. The following table lists the maximum wall thickness for each unit type: Unit type Max.
Installation Unpacking 4.1.4 4 Installation diagram: 1. Connect the cables as shown to the following diagram: [1] [2] [3] [4] DC 24 V RS232 / RS422 / RS485 RS232 / RS422 / RS485 Ethernet DC 24 V [5] Ethernet 8832896395 [1] [2] [3] [4] [5] Make sure that the operator panel and controller have the same electrical grounding (reference voltage value), as otherwise there may be problems with communication. Use an M5 screw and a PE (as short as possible) with a minimum cross section of 2.5 mm2.
Installation Mounting the operator panel 4 4.3 Mounting the operator panel How the operator panel is mounted depends on the unit type: • DOP11C-40, -70 and -100 Use all the retaining slots and the brackets and screws supplied to mount the operator panel. 0.5 - 1.0 Nm 4249326347 • 4249328011 DOP11C-120 and DOP11C-150 Mount the operator panel to its designated spot using 8 screws (Torx, M4). Loosen the screw [1] with a screw driver (Torx, TX7) [2] until the retaining clamp tilts up.
Installation Connecting a voltage supply 4.4 4 Connecting a voltage supply NOTICE Ensure correct polarity when connecting the panel. Incorrect polarity will damage the unit. INFORMATION Make sure the operator panel and the controller system have the same electrical grounding (reference voltage value). Otherwise, communication errors might occur.
Installation Connecting the operator panel 4 4.5 Connecting the operator panel 4.5.1 Preparation NOTICE Possible damage to property. The power must be switched off when connecting the units. • Take suitable measures to prevent the motor from starting up unintentionally via the connected frequency inverter. – Disconnect the electronics input X13.
Installation Connecting the operator panel 4.5.2 4 Connecting the operator panel to the frequency inverter and PC 1. Connect the operator panel to the inverter. For detailed information, refer to chapter "RS485 connection" (page 26). RS485 RS485 8997683979 2. Connect the operator panel to the PC using the standard Ethernet patch cable. INFORMATION The Ethernet interface of the operator panel has an "autocrossing" function.
Installation Connecting the operator panel 4 4.5.3 Connection types RS-485 connection With the RS485 interface you can connect up to 31 MOVIDRIVE® units to one operator panel. DOP11C can be directly connected to a frequency inverter of the type MOVIDRIVE® via the RS485 interface using a 9-pin Sub-D connector.
Installation Connecting the operator panel 4 Pin assignment for DOP11C: DOP11C MOVITRAC® 9-pin D-Sub socket Jumper between 1 and 6 to activate bus termination 120 ohms 0.25 W MOVIDRIVE® S1 Control unit S2 /Controller inhibit CW/stop* CCW/stop* Enable/rapid stop* n11/n21* n12/n22* Reference X13:DIØØ...
Installation Connecting the operator panel 4 Potential shift NOTICE There must not be any potential shift between the units connected to RS485. Take suitable measures to avoid potential shift, for example, by connecting the unit grounds (GND) with a separate cable, connecting the voltage supply (24 V) etc. Ethernet connection Connecting DOP11C to a PC for programming and remote maintenance via Ethernet and TCP/IP.
Startup Important notes on startup 5 I 5 0 Startup WARNING Risk of injury due to electric shock. Severe or fatal injuries. • 5.1 Adhere to the safety instructions in chapter 2 during installation. Important notes on startup For a successful startup, a correct electrical connection of the operator panel is required. WARNING The operator panels of the DOP11C series may not execute any safety functions without higher-level safety systems. Severe or fatal injuries.
I 5 0 5.2 Startup Starting the unit Starting the unit INFORMATION Units are delivered without an uploaded project. The unit starts automatically and shows the start screen on the display when it is connected to a voltage supply. Basic settings (e. g. IP addresses) can be set in the service menu. • Touch the start screen to open the service menu.
Operation Open service menu 6 Operation 6.1 Open service menu 6 INFORMATION For the following procedure, a project has to be uploaded into the service menu. Proceed as follows to switch to the service menu: 1. Connect the operator panel to the voltage supply. An hourglass appears on the screen. 2. Wait until the hourglass disappears. 3. Touch the display and keep the finger on the display until the following message appears: "Tap anywhere on screen, or touch calibrate will start in 10 seconds" 4.
kVA 7 i f n Technical data and dimension sheets Technical data P Hz 7 Technical data and dimension sheets 7.1 Technical data 7.1.1 Part numbers Part number 7.1.
kVA Technical data and dimension sheets Technical data 7.1.3 i f n 7 P Hz Display DOP11C-40 DOP11C-70 DOP11C-100 DOP11C-120 DOP11C-150 Graphics resolution (pixels) 480 x 272 (16:9) 800 x 480 (16:9) 640 x 480 (4:3) 1280 x 800 (16:10) 1280 x 800 (16:10) Active screen size, WxH 95.0 x 53.9 mm (4.3") 152.4 x 91.4 mm (7") 211.2 x 158.4 mm (10.4") 261.12 x 163.2 mm (12.1") 331.2 x 207.0 mm (15.4") Backlight LED, can be dimmed >50,000 h at an ambient temperature of +25 °C.
7 kVA i f n Technical data and dimension sheets Technical data P Hz 7.1.6 Certifications DOP11C-40 EMC tests on panel UL approval DOP11C-70 DOP11C-100 DOP11C-150 UL 508 In association with the UL approval, the installation guides (in English) delivered with the unit and with the following document numbers apply: 20162944 / EN 20194544 / EN 20194943 / EN DNV approval 20195346 / EN 20195745 / EN Yes NEMA 7.1.
kVA Technical data and dimension sheets Pin assignment 7.2 Pin assignment 7.2.1 Serial connections i f n 7 P Hz 9-pin D-sub connector Diagram connector 1 6 7 2 3 8 terminal no.
7 kVA i f n Technical data and dimension sheets Cable P Hz 7.3 Cable 7.3.
Technical data and dimension sheets Dimension sheets 7.4 Dimension sheets 7.4.
kVA 7 i 7.4.
Technical data and dimension sheets Dimension sheets 7.4.
Technical data and dimension sheets Dimension sheets 7 Dimension sheet DOP11C-120 maximal 8 mm material thickness 9 224 242 9 7.4.
Technical data and dimension sheets Dimension sheets i f n 7 P Hz Dimension sheet DOP11C-150 9 286 268 9 7.4.
Declaration of conformity 8 8 Declaration of conformity EC Declaration of Conformity 6(: (852'5,9( *PE+ &R .
Appendix Chemical resistance 9 Appendix 9.1 Chemical resistance 9.1.1 Metal housing 9 The frame and housing are made of powder-coated aluminum.
Appendix Chemical resistance 9 9.1.
SEW-EURODRIVE—Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 76642 BRUCHSAL GERMANY Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.