Introduction:
The ProVantage
®
Glass Block Installation System is the
easiest way to install Seves Glass Block 4-in Series
(4" thick) Glass Block, and get professional results.
ProVantage
®
I Installation System
(Channel Construction):
This method is used to install straight walls in
4-sided openings.
In this method, glass block is installed in a
perimeter channel.
The maximum opening size for exterior panels is
50 square feet.
The maximum opening size for interior panels is
85 square feet.
• Thejointsofthesepanelscanbenishedwith
acrylicpolymermodiedsandedgrout.
ProVantage
®
II Installation System
(Anchor Construction):
This method is used to install straight and 90° angled
walls attached at two, three or four sides.
In this method, glass block panels are secured to
the wall using special wall anchors.
The maximum opening size for exterior panels is
50 square feet, framed on all four sides.
The maximum opening size for interior panels is
85 square feet, framed on at least two sides.
• Thejointsofthesepanelscanbenishedwith
acrylicpolymermodiedcementbasedgrout.
Sealantnishingcanonlybeusedonstraightwallsin