Installation Guide

1 4” 8”
2 7- 1/16 15 - 1/2
3 11 - 1/4 23 - 1/4
4 14 - 7/8 31 -7/8
5 18 - 1/2 38 - 1/2
6 22 - 1/8 46 - 1/8
7 25 - 3/4 54
8 29 - 3/8 61 - 5/8
9 33 69
10 36 - 5/8 77
11 40 - 1/4 84 - 5/8
12 43 - 7/8 92 - 1/4
3
Channel Construction Installation
Method
#
1 — Straight Applications Only
1. PrePare the OPening
A. Make sure the opening is the correct size. Use the table below
to find the correct dimensions for a straight glass block wall
anchored using a horizontal floor channel and two vertical
channels in a framed opening.
Installation Method
#
1
Perimeter Channel Construction
Design Line 80mm metric
Number
of Blocks
Rough Opening Width and Height
(Inches)
Note: Blocks are available in 90 mm and
190 mm sizes (3 - 1/2” and 7- 1/2”)
For panels larger than 12 block in width or height:
Add 3 - 5/8” for 90 mm wide block
Add 7 - 5/8” for 190 mm wide block
90mm Block Width
(3-1/2”)
190mm Block Width
(7-1/2”)
*For Rough Openings Height, Add 1/4” to Width Measurement.