EG - SAFETY DATA SHEET subject to the regulations 1907/2006/EG
Product Name: Steam-Smoke-Distillate / Smoke Fluid
Generation Date: 30.05.2017
Version: 1.2
___________________________________________________________________________
Page 4 of 13
Inappropriate Extinguishing Media: Straight streams of water:
5.2 Special hazards arising from the mixture
Hazardous Combustion Products: Incomplete combustion products, Oxides of carbon, Smoke.
5.3 Advice for fire fighters
Fire Fighting Instructions: Evacuate area. Prevent run-off from fire control or dilution from
entering streams, sewers or drinking water supply. Fire-fighters should use standard protective
equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water
spray to cool fire exposed surfaces and to protect personnel.
Unusual Fire Hazards: Combustible.
FLAMMABILITY PROPERTIES
Flashpoint [Method]: >62°C (144°F) [ASTM D-93]
Upper/Lower Flammable Limits (Approximate volume % in air): LEL: 0.6 UEL: 7.0
(Extrapolated)
Autoignition Temperature: >200°C (392°F) [ASTM E959]
SECTION 6 ACCIDENTAL RELEASE MEASURES
6.1 Personal precautions; protective equipment and emergency procedures
PROTECTIVE MEASURES
Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind
areas if required, due to toxicity or flammability of the material. See Section 5 for firefighting
information. See the Hazard Identification Section for Significant Hazards. See Section 4 for
First Aid Advice. See Section 8 for advice on the minimum requirements for personal
protective equipment. Additional protective measures may be necessary, depending on the
specific circumstances and/or the expert judgement of the emergency responders.
6.2 Environment precautions
Land Spill: Stop leak if you can do so without risk. Absorb or cover with dry earth, sand or
other noncombustible material and transfer to containers. Recover by pumping or with suitable
absorbent.
Water Spill: Stop leak if you can do so without risk. Confine the spill immediately with booms.
Warn other shipping. Remove from the surface by skimming or with suitable absorbents. Seek
the advice of a specialist before using dispersants.
Water spill and land spill recommendations are based on the most likely spill scenario for this
material; however, geographic conditions, wind, temperature, (and in the case of a water spill)