Specifications
13
5. When you reach the desired sample size, REMOVE the requested num-
ber of pieces from the container.
6. Press the count key. If the sample size is not large enough to satisfy
the minimum accuracy requirement the display will read “Sub nnn”
PC. Remove the specified number of pieces (i.e., nnn) from the con-
tainer and press the count key again.
7. Remove pieces until the display reads the number of pieces you wish
to count out or kit.
8. Press the zero key.
9. Repeat Steps 7 and 8 as many times as needed.
LOCKED SAMPLE SIZE
The sample size used by the scale for determining the average piece weight
can be locked to accelerate the sampling and counting process. Once the
sample size is locked, the user will not have to choose a sample size before
adding the sample to the scale.
LOCKING THE SAMPLE SIZE
To lock the sample size, follow this procedure:
1. Remove all weight from the pan and press zero. The scale will display
“0.00”.
2. Press the sample size key (EZ6) or the count key (EZ2). The scale will
display “Add 10.”.
3. Repress the sample size key (EZ6) or the count key (EZ2) until the
desired sample size is displayed.
4. Press and hold the count key for 5 seconds until the scale beeps.
5. The scale will return to weight display, “0.00”. The sample size is now
locked.