Specifications

12
(The sample size requirement can be increased by pressing the sample
size (EZ6) or count (EZ2) key repeatedly. The predetermined sample
sizes are: 10, 25, 50 and 100 pcs. A custom sample size may be preset
using the minimum sample size setup. If preset, the scale will never
request a sample size less than the preset minimum sample size.)
3. When you reach the desired sample size, place the requested number
of pieces in the container.
4. Press the count key. Wait for the “OK” symbol then slowly add pieces
until the displayed count is increased by 100% or less.
5. Press the count key. The scale displays “UPdAtE” and automatically
calculates a new average piece weight based on the larger number of
pieces. If “UPdAtE” is not displayed, the additional pieces have ex-
ceeded 100% of the previous sample weight and the APW will not be
updated.
NOTE: The accuracy enhancement feature is disabled if the average piece
weight has been scanned in from a bar code or entered via a
computer.
REVERSE COUNTING OR KITTING
Using this feature, you can place a container full of pieces on your scale and
count the number of pieces removed. This is especially helpful when kitting
(counting out a certain number of pieces to be packed together). To per-
form reverse counting or kitting, use the following procedure:
1. Place a container full of pieces you wish to count on the pan.
2. Press the zero key.
3. Press the sample size (EZ6) or count (EZ2) key.
4. The scale display will say “Add 10.” PC.
(The sample size requirement can be increased by pressing the sample
size (EZ6) or count (EZ2) key repeatedly. The predetermined sample
sizes are: 10, 25, 50 and 100 pcs. This sequence of predetermined
sample sizes will repeat itself as the sample size key is pressed. A
custom sample size may be preset by using the minimum sample size
setup feature. If this is the case, the scale will never request a sample
size less than the preset minimum sample size.)