Product specifications
Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com ©2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
DIFFERENTIAL PRESSURE
8
Model 260
Pressure Transducer
■ Optional 4 Digit LCD
■
■
■ Simple 5-Step Setup
■
■ Hinged Cover
■ External Mounting Tabs
■
■
Guarantees Range to Range Performance
■ NIST Traceable
■
■ Meets CE Conformance Standards
TARGET USERS
■
■ Small Users - Inventory & Installation Savings
■ Sub-Contractors - Quick Installation
■
■ Service Technicians - Quick & Accurate
Recongurations
The calibration of this product is NIST traceable.
U.S. Patent nos. 6019002; 6014800
DESCRIPTION
Ideal for installers who are unsure of the exact job requirement,
the Model 260 gives the installer the ability to “congure on the
y”. The Model 260 oers user-selectable unidirectional and
bidirectional pressure ranges and analog outputs, a standard
Pollution Control.
SPECIFICATIONS
Performance Data Environmental Data Electrical Data (Voltage)
Standard Operating Temperature
3
32 to 122°F (0 to 50°C) Circuit 3-Wire (Com, Out, Exc)
Accuracy RSS
1
(at constant temp) ±1.0% FS
Physical Description
Excitation 13 - 30 VDC/18-24 VAC
Non-Linearity, BFSL
±0.96% FS
Case Fire-Retardant Glass Filled Polyester (UL 94 V-0
Approved), Hinged Lid
Field Selectable Output
4
0 to 5 or 0 to 10 VDC
5
Hysteresis 0.10% FS
Mounting Two External Screw Holes
Vertical Position
Bidirectional output at zero
pressure
0 to 5 VDC = 2.5 VDC
0 to 10 VDC = 5 VDC
Thermal Eects
2
Electrical Connection Block Removable Screw Terminal Output Impedance 300 ohms
Compensated Range ºF (ºC) 32 to 122°F (0 to 50°C)
Pressure Fitting 3/12” O.D. Barbed Brass
Electrical Data (Current)
Zero Shift %FS/ºF(ºC) 0.03 (0.054) Zero Push Button Circuit 2-Wire, Reverse Wiring Protected
Maximum Line Pressure 10 PSI
Span Push Button
Excitation 24 V (DC only)
Overpressure Up to 10 PSI Weight (approx.) 8 Ounces External Load 0 to 800 ohms
Max. Line Pressure 10 PSI
Pressure Media
Field Selectable Output
4
4 to 20 mA
7
Overpressure Up to 10 PSI
(range depedent)
Typically air or similar non-conducting gases. Max. Loop Supply Voltage (VDC) 30 + 0.004 x (resistance of
receiver plus line)
Long Term Stability (max.) 2.0% FS/YR
1
RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
2
Units calibrated at nominal 70˚F. Maximum thermal error computed from this datum.
3
Operating temperature limits of the electronics only. Pressure media temperatures may be consider-
ably higher.
4
Calibrated into a 50K ohm load, operable into a 10K ohm load or greater.
5
Span (Full Scale) output factory set to within 1%.
6
Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
7
Span (Full Scale) output factory set to within ±0.16mA.
Specications subject to change without notice.
Bidirectional output at zero
pressure
12 mA
7
Position Eect
External Load 0 to 800 ohms
Zero Oset %FS/G 0.2% Minimum Supply Voltage (VDC)
Maximum Supply Voltage (VDC)
13 Volts (at terminal)
30 Volts (at terminal)
(Unit is factory calibrated at 0g eect in the vertical position)