Product specifications
©2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com
DIFFERENTIAL PRESSURE
77
Model 209
Pressure Transducers
The Model 209 voltage output is a 3-wire circuit. If the
209 is supplied with 2 feet of cable, the electrical connec-
tion is as follows:
Model 209
Setra Transducer
(4-20 mA)
Power
Supply
Load
(Monitor)
+
+
+
_
_ _
Red
4-Pin Packard Connector
D
Type: Metri-Pack 150
+ Excitation
+ Output
Common
Type: Metri-Pack 150
Negative
Positive
Type: G4A1M#931807-106
Common
+ Output
+ Excitation
Negative
Positive
Type: P2S Series 150
Common
+ Output
+ Excitation
Type: P2S Series 150
Posi-
Negative
Hirschmann Connectors
Current
Current
Current
Red + Excitation
Monitor
or
Control
Device
Shield
+Out Green
-Out White
Current Output
The Model 209 True 2-wire device. If the 209 is supplied
with 2 feet of cable, the electrical connection is as fol-
lows:
-
nector
Type: G4A1M#931807-106
Current
+
–
– +
– +
–
+
SPECIFICATIONS
Performance Data Environmental Data Electrical Data (Voltage)
Accuracy RSS
1
(at constant temp) ±0.25% FS
Operating
3
Temperature °F (°C) -40 to + 185 (-40 to +85) Circuit 3-Wire (COM, OUT, EXC)
Non-Linearity, BFSL
±0.22% FS
Storage Temperature °F (°C) -40 to + 185 (-40 to +85) Excitation 9 to 30 VDC
Hysteresis 0.10% FS
Shock
3
200g operating Output
6
0.5 to 5.5 VDC
7
Non-Repeatability 0.05% FS
Acceleration 10 g Maximum
5
Output Impedance 10 ohms
Thermal Eects
Shock
3
200g Operating
Electrical Data (Current)
Compensated Range °F (°C) -4 to +176 (-20 to +80)
Vibration
4
20g Circuit 2-Wire
Zero Shift %FS/100°F (%FS/50°C) ±2.0 (±1.8)
Environmental Protection Weather Resistant Output
8
4 to 20mA
9
Span Shift %FS/100°F (%FS/50°C) ±1.5 (±1.3)
Physical Description
External Load 0 to 800 ohms
Warm-up Shift 0.1% FS Total
Case Stainless Steel & Valox Minimum supply voltage
(VDC)
9+ 0.02 x (Resistance of receiver
plus line)
Response Time 5 milliseconds
Sensor 17-4 PH Stainless Steel Maximum supply voltage
(VDC)
30+ 0.004 x (Resistance of receiver
plus line).
Long Term Stability 0.5% FS/1 YR
Electrical Connection 2 ft. multiconductor cable
1
RSS of Non-Linearity, Hysteresis, and Non-Repeatability.
2
Note: Hydrogen not recommended for use with 17-4 PH Stainless Steel.
3
Mil-Std. 202, Method 213B, Cond. C
4
Mil-Std. 202, Method 204, Cond. C
5
See ordering information for other ttings available (minimum quantities apply).
6
Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
7
Zero output factory set to within ±50mV. Span (Full Scale) output factory set to within ±50mV.
8
Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load.
9
Zero output factory set to within ±0.16mA. Span (Full Scale) output factory set to within ±0.16mA.
Specications subject to change without notice.
Pressure Media
Pressure Fitting
5
1/4” -18 NPT external, 17-4 PH Stainless Steel
Liquids and gases compatible with 17-4 PH Stainless Steel.
2
Vent Through cable
Weight (approx.) 2.3 ounces (65 grams)
GAUGE PRESSURE