User Guide

Compressor station
Functions and features.
This is an electronic device which has the function of piloting the motor of the compressor and carrying
out all the controls and electrical protection of the system.
Its main features are as follows:
a) Protection of the battery through automatic turning off of the compressor when the feeding voltage
reaches the minimum threshold.
b)The compressor will start up again automatically when the voltage goes back to normal values.
- This model can be fed equally using 12/24V or mains power 110 -120V (100 - 240V)AC.
- Can connect with 110-120V (100-240V) AC with AC Adapter.
- The refrigerator is provided with automatic switch over from one kind of feeding to the other.
- Should both be present at the same time, the device will always set itself on mains power priority feeding
by 110 - 120V (100 - 240V) AC.
USING THE REFRIGERATOR AT HOME
ELECTRONIC CONTROL
CUT IN / CUT OUT
● Your fridge has built in battery protection and needs a minimum 10.9 V to start and 9.6 V to continue operating.
● During operation a load is placed on the power supply and voltage can drop by as much as 2 V, especially if the
wiring in insufficient (less than 6mm direct to battery) or if there is a loose connection somewhere.
● If this occurs when you try and start your SetPower and the power supply drops under 10.9 V it will not start.
If this occurs when your SetPower is running and the power supply drops below 9.6 V it will stop.
COMMON 12V POWER SUPPLY ISSUES
Wiring
Often the standard wiring from the car battery to the 12V outlet is too small.
A minimum 6mm automotive wiring should be used and the earth should be
wired directly back to the battery.
Battery
The car battery could be old, undersized or have a dead cell causing too
much voltage drop.
Connections
The 12 V plug, car 12 V socket or any of the connections between the
fridge and the battery could be faulty or have come loose since installation.
6