User guide
ST-EG100-E Installation and User Guide Maintenance & Troubleshooting
Figure 11 - SETECH Updater Discovery Window
6. Left-click to highlight the Ethernet board to update, and activate the Select button.
NOTE: For most security systems, only a single Ethernet board is listed.
7. Activate the File… button and browse to select the firmware binary file to install. The binary
file includes the last 6 characters of the MAC address of the Ethernet hardware. In the
example shown, the binary file for the Ethernet board with a MAC address of
00:40:9D:69:51:FF would be STEG100E_6951FF.bin.
The filename and path is loaded into the Image entry box in the SETECH Updater window.
8. Activate the Update button to start the update process (see Figure 12).
!
CAUTION
The update process takes several minutes to complete. Do not interrupt or remove
power from the Ethernet board until the update process is complete. An interruption
of the update process may result in the Ethernet board becoming non-responsive. If
the update process is interrupted, repeat update process starting at step 6. If the
Ethernet board is unresponsive and the update process cannot be restarted, refer to
Section 5.2 for troubleshooting information.
Figure 12 – Operating System Firmware Update In Process
9. At the completion of update process, the system displays the message “Update complete” at
the bottom of the SETECH Updater window.
SETECH Security & Automation Revision 1
96-300001 Page 41 of 44