User guide

ST-EG100-E Installation and User Guide Virtual Keypad
Displays a list of system defined macros. Macros are defined using the ELK configuration tool
and can be used to automate operations (e.g. set all lights to a specific level). Clicking on the
status LED requests the task be activated and at that time the LED will turn green. Once the
request has been acknowledged, the LED will return to its original state.
4.4.5. Outputs Page
The output display shows the current state of the system defined outputs with the “Show” option
enabled. By default, only the first 32 available outputs are displayed. To display outputs 64 to
208, the “Show Output >32” check box needs to be selected within ElkRP2. The outputs are
displayed in a list by output number, with their assigned name and the current state of the output.
Selecting an output from list will highlight that output and update the displayed output state. The
current state is shown by a green indicator for an output that is on or a gray indicator for an
output that is off. The selected output state can be toggled from on to off or off to on
immediately by clicking on the output state indicator. Additionally, the output state can be
turned on for a specified duration by specifying the duration in hours, minutes and seconds using
the input boxes and selecting the “Turn On” button.
SETECH Security & Automation Revision 1
96-300001 Page 34 of 44