User guide
ST-EG100-E Installation and User Guide Virtual Keypad
¾ Auto - Maintains the ambient temperature between the heating and
cooling setpoints.
¾ Emergency Heat - Forces use of heating coils on heat pump furnaces.
This mode has no effect for non-heat pump units.
• Fan - Controls the blower operation.
¾ Auto - Fan is cycled on/off based on the operation mode and setpoints.
¾ On - Fan runs continuously.
¾ Cycle - Fan is cycled on and off (based on the configuration of the
thermostat) to circulate the air (Omnistat2 only).
• Hold - Controls program schedule temperature settings.
¾ Off - Thermostat responds to program schedule temperature setting
changes.
¾ On - Thermostat ignores program schedule temperature setting
changes.
¾ Vacation - Thermostat ignores program schedule temperature setting
changes for the duration of the scheduled away time (Omnistat2 only).
4.4.3.2. Temperature Probes
SETECH Security & Automation Revision 1
96-300001 Page 32 of 44