Specifications

Water Tank Level Wiring
(a) Empty the water from the tank(s)
(b) Choose a suitable side of the tank where the level-sensing bungs can be
located.
(c) Drill the required holes as shown in Figure 5 below.
(d) Fit the four bungs to the holes as detailed in Figure 6. Pay particular attention
to which bung goes into which hole, matching the wire colours as shown in Figure
6.
(e) Connect the pump and remote on/off switch as detailed in Figure 7 (assuming
Setec power supply is used). If used with other power supplies, connect according
to Figure 8.
(f) Connect the water-tank sensors as detailed in Figure 9.
(g) Fill the tank(s) and check for water leaks around the bungs. Reseal as
necessary.
(h) Test operation of water level sensors, water pump switch, and remote on/off
switch.
19