DIAGNOSTICS
The diagnostics page will display any detected faults in the
system.
To clear circuit faults, remove the suspected short and toggle
the suspected output to clear the fault indicator.
1. For lights, tank heaters, water heaters, water pumps,
electric heaters or gas heaters, if a short occurs on these
outputs, a red fault indicator will appear.
FIGURE 55: Gas Water Heater Warning
FIGURE 54: Red Fault Indicator
2. The gas water heater has its own warning output. If it signals a fault, a warning
will appear on the gas water heater button.
3. The motor outputs do not indicate a warning if the wires are shorted.
4. If a fault occurs on a Climate output (e.g. the compressor output), a fault icon
will appear in the zone. To clear the Climate fault, diagnose that Climate zone,
remove the short, turn the Climate off and then turn it back on to reset the
fault display.
FIGURE 53: Device
Information Screen