Servosila-Device-Reference-0xA020192
Table Of Contents
- Servosila Device Reference
- Configuration Parameters
- Configuration - Datasheet
- Configuration - Control Laws
- Configuration - Features
- Configuration - Brake
- Configuration - Work Zone
- Configuration - Fault Management
- Configuration - Peripheral: GPIO
- Configuration - Peripheral: Hall Sensors
- Configuration - Peripheral: Quadrature Encoder
- Configuration - Peripheral: SSI/BISS-C Encoder
- Configuration - Peripheral: SPI Encoder
- Configuration - Peripheral: PWM Encoder
- Configuration - Peripheral: Gate Driver
- Configuration - Networking
- Configuration - Product Activation
- Telemetry Parameters
- Telemetry - System Status
- Telemetry - Field Oriented Control (FOC)
- Telemetry - Direct Drive Control
- Telemetry - Sensorless Observer
- Telemetry - Hall Sensors Observer
- Telemetry - Peripheral: ADC
- Telemetry - Peripheral: Hall Sensors
- Telemetry - Peripheral: Quadrature Encoder
- Telemetry - Peripheral: SSI/BISS-C Encoder
- Telemetry - Peripheral: SPI Encoder
- Telemetry - Peripheral: PWM Encoder
- Telemetry - Peripheral: GPIO
- Telemetry - Peripheral: Inverter (PWM)
- Telemetry - Peripheral: Gate Driver
- Telemetry - Networking
- Telemetry - Device Information
- Commands
- Command - Electronic Speed Control (ESC), Hz
- Command - Electronic Speed Control (ESC), RPM
- Command - Servo
- Command - Servo Stepper
- Command - Current Control / Field Oriented Control (FOC)
- Command - Electronic Torque Control (ETC)
- Command - Direct Field Control: Rotation
- Command - Direct Field Control: Electrical Position
- Command - Kickstart
- Command - Reset
- Command - Reset Work Zone
- Command - Brake
- Command - Stop
- Command - Off
- Command - GPIO: PWM output
- Command - Testing: Field Oriented Control (FOC)
- Command - Testing: Electronic Speed Control (ESC)
- Command - Testing: Servo Control
- Command - Brushed: Open Loop Control (1-2 motors)
- Command - Autoconfiguration: Brushless Motor
- Command - Autoconfiguration: Brushed Motor
- Command - GPIO: Generic Output
- Telemetry Mappings (TPDO)
- Configuration Parameters
0x5009,
0x05,
ro
3
Limit Switch (Positive Speed) 0 or 1 Status of Limit Switch in POSITIVE speed direction. UINT16,
0x5009,
0x06,
ro
4
Generic Input 0 or 1 Latest value read out from a dedicated GPIO input. UINT16,
0x5009,
0x10,
ro
Telemetry - Peripheral: Inverter (PWM)
# Parameter Units Description CANopen
1
Inverter (PWM) mode 0 or 1 • 0: Inverter PWM is OFF
• 1: Inverter PWM is ON
BOOL,
0x5002,
0x02,
ro
2
CMPR A CPU ticks A silicon-specific value UINT16,
0x5002,
0x03,
ro
3
CMPR B CPU ticks A silicon-specific value UINT16,
0x5002,
0x04,
ro
4
CMPR C CPU ticks A silicon-specific value UINT16,
0x5002,
0x05,
ro
Telemetry - Peripheral: Gate Driver
# Parameter Units Description CANopen
1
driver: mode 0 or 1 • 0: Gate Driver is OFF
• 1: Gate Driver is ON
BOOL,
0x5004,
0x02,
ro
2
driver: fault 0 or 1 This is a latest reading of the "FAULT" signal coming from the Gate
Driver chip.
BOOL,
0x5004,
0x03,
ro
3
driver: overcurrent or
overtemperature
0 or 1 This is a latest reading of the "OVERCURRENT or
OVERTEMPERTATURE" signal coming from the Gate Driver chip.
BOOL,
0x5004,
0x04,
ro
50 www.servosila.com