User guide

SerVision MVG 400 System Guide
Installing the MVG 400 System 29
Figure 15: Power LED
NOTE: When the start-up process is completed, if the Power LED does not flash – it
displays as a solid green or orange all the time – the start-up process was not
successful. In this case, disconnect the unit from the power supply and then
reconnect it.
NOTE: It is recommended that only vehicle installation specialist connect the unit to the
battery.
Connecting the Unit to the Vehicle Battery
Normally, the unit is connected to the vehicle battery and to the ignition using 16 AWG cable
(not supplied). This can be done in one of two ways:
Connecting the unit directly to the battery and the ignition
Connecting the unit to a power source in the vehicle that is only active when the ignition
is on
When the unit is connected to the battery and ignition in one of these ways, it automatically
powers up when the ignition is switched on. If the unit is connected directly to the battery, it
can be configured to operate only when the vehicle ignition is on or to shut down
automatically soon after the ignition is turned off. Otherwise, it will shut down automatically
when the ignition is turned off.
For testing and evaluation purposes, the unit can also be powered by connecting it to the
vehicle’s cigarette lighter, if the vehicle has one. This method connects the unit to the battery
and the ignition quickly and easily, but it is not normally suitable for permanent connections,
because it is difficult to install the unit and the wiring securely in appropriate locations when
this method is used.
In addition, it is possible to connect the unit to the battery alone, without connecting it to the
ignition. In this case, the unit runs continuously, whether the ignition is on or not, as long as
the battery can supply power to it. Because of the drain on the battery, connecting the unit in
Power LED