User guide
SerVision MVG 400 System Guide
Installing the MVG 400 System 20
Figure 10: Connecting sensors to the ADAM-4051 module
3. Connect the ADAM-4051 module to the ADAM-4520 isolated converter as follows (see
figure 12, page 22):
Connect this connector on
the ADAM-4051
To this connector on the
ADAM-4520
(Y) Data+ Data+
(G) Data- Data-
(R) +Vs (R)+Vs
(B) GND (B)GND
4. Connect the ADAM-4520 isolated converter to the RS232/485 connector on the rear
panel of the MVG 400 unit in one of the following ways:
• If you are not connecting any RS485 PTZ controllers to the unit, using the 9-pin
flat ribbon cable, connect the RS232 connector of the ADAM-4520 converter
directly into the RS232/485 connector.
• If you are also connecting one or more RS485 PTZ controllers to the unit, using the
9-pin flat ribbon cable, connect the RS232 connector of the ADAM-4520 converter
into the RS232 connector of the RS232/485 adapter supplied with the unit. Connect
the PTZ controllers to the adaptor as explained under Connecting PTZ Controllers,
page 16. Then plug the adaptor into the RS232/485 serial port connector on the
unit.
D GND
Connect sensor
g
round
wires to this connector
D1 0 through D1 10
Connect positive (+) sensor wires
to these connectors
D1 11 through D1 15
Connect positive (+) sensor
wires to these connectors
D GND
Connect sensor
g
round
wires to this connector