User guide

SerVision MVG 400 System Guide
Installing the MVG 400 System 18
The switch can then be used to change the active outline. For additional information, see
Outlines, page 124; Sensor and Activator Settings, page 115.
Note: Some alarm panels can also be connected to In1. When they are, they can function
as automatic outline toggle switches. For additional information, please consult the alarm
panel vendor.
In4: If a CCTV monitor will be connected to the unit, you can connect a push-button
switch to In4 instead of a sensor. The button can then be used to change the display on
the monitor. For additional information, see Connecting a CCTV Monitor, page 24;
Configuring a CCTV Monitor (TV-Out), page 54; Sensor and Activator Settings,
page 115.
D
D
D
To connect a sensor or switch directly to the unit:
1. Install the sensor or switch in its desired location in accordance with the manufacturer's
instructions.
Note: If the sensor requires an external power supply, you may be able to connect it to
the 12 VDC connector on the rear panel of the unit. However, bear in mind that the unit
can supply a maximum of 500 mA of power. If the devices connected to the unit require
more than this amount of power, you must power some or all of them independently.
2. Connect the two wire contacts of the sensor or switch to the Sensors terminal block on
the rear panel of the MVG 400, as illustrated in figure 7. Insert the wires into the
connectors and tighten the screws below each connector to hold the wires in place.
Note: The wires must be connected to two adjacent contacts in the same group (e.g. the
two contacts of “In1”), but the polarity does not matter.
Figure 7: Connecting a sensor
Connecting Sensors Using an ADAM Module
If you want to connect more than four dry sensors to the MVG 400, you can do so by
connecting an ADAM Data Acquisition Module to the unit. Up to 16 additional dry sensors
can then be connected to the unit through the ADAM module.
To connect sensors using an ADAM module, you will need the following items:
ADAM-4051 Data Acquisition Module (available from SerVision)
ADAM-4520 isolated RS232->RS422/RS485 converter (available from SerVision)
In1 In2 In3 In4
Sensor
MVG 400 rear panel
Sensors terminal block