User Guide

You should not need tools to make a satisfactory seal; excessive force may
damage the connections (Fig 10). It should be sufficient to firmly tighten
them by hand.
Permanent Plumbing
Please make provisions to shut off the water supply to the appliance completely. A separate isolation valve
should be fitted. This will:
1 Avoid the possibility of flooding when the machine is not in use.
2 Allow the appliance to be moved for cleaning and servicing. If you do not
have an existing installation for connecting your appliance, consult a
qualified plumber. There are various methods available.
Discharge into a standpipe - drainage
The top of the standpipe should be approximately 610mm (24") from the
ground. The dimensions from the floor to the underneath of the bend in the
drain hose, should be between 570 - 670mm (22
1
/2"-26
1
/2") (Fig 13). The
take off pipe must be capable of taking a flow of 6 gallons (27 litres) per
minute. The minimum diameter of the standpipe must be 3.81cm (1
1
/2") and
there must be an air gap around the appliance drain hose when fitting into
the standpipe.
Recommended way to plumb in a washer dryer from a combined
waste trap
38mm (1
1
/2")
Min
Air gap
Ins
p
ection Elbow
570 - 670mm
(22
1
/2" - 26
1
/2")
W A S H I N G M A C H I N E
8
Fig 10
Fig 12
Fig 11
Fig 13
Washing Machine Handbook 7/9/04 12:24 PM Page 10