Installation guide

SL-KXSA-300 ServerLink Cat 5 KVM Extender VGA, USB, PS/2, Audio & Serial up to 300mtr
3
TX Audio: [ON/OFF]
Activate or deactivate the TX Audio (and Mic) on the
TX unit. When the TX audio is OFF, you can no
longer hear the sound or use the microphone on the
computer on the TX unit.
EDID Setting
The EDID setting on the RX can either be configured
as the same as the monitor on the computer on the
TX, or as the monitor used on the RX.
EDID Setting Submenu
TX EDID
You can select the TX EDID emulation data set to
adopt - either that of the monitor on the RX or the
monitor on the TX unit. However, before you can
make the selection for the first time, you may need to
read the monitor EDID information by the Read
Monitor option below.
Read Monitor
Reads the EDID configuration data from the monitors
on the TX and the RX and stores it for use for the
EDID emulation on the TX unit.
Note that the RX unit will always utilize the EDID
configuration data from the monitor connected to the
RX unit itself. However, the TX unit is able to use the
EDID configuration data from the monitor connected
to the TX unit itself or the EDIDI configuration data
from the monitor connected to the RX unit.
RS-232 Setting
RS-232 Setting Submenu
Baud Rate: [9600, 14400, 19200, 38400, 57600,
115200]
Select the Baud Rate of the RS-232 connection.
Data bits: [5, 6, 7, 8]
Select the Data bits of the RS-232 connection.
Stop bits: [1, 2]
Select the Stop bits of the RS-232 connection.
Parity: [Odd, Even, None]
Select the Parity of the RS-232 connection.
Password Setting
Disable / Enable the password protection feature. If
enabled, after you log out or the Auto logout has
timed out, you will be prompted for the correct
password before you can access the console again.
Auto Logout
[0 ~ 10]
Disable / Enable the Logout timeout (0~10min, 0 =
Disable).
The Auto logout time can be configured from 0
(Disable), with an increment of 1, right up to 10 min.
If the password protection is not enabled, the Auto
logout will not be available for use.
Hotkey
[SCROLL, CAPS, NUM, F12]
By default, the hotkey preceding sequence is
SCROLL + SCROLL. However it can be changed to
an alternative hotkey such as CAPS, F12 or NUM.
OSD Timeout
[0~63]
Configure the OSD timeout value (0, 20~...30~…60),
with an increment of 5 seconds, (0 = Disable).
Load Default
Load factory default settings.
HOTKEYS AVAILABLE ON THE RECEIVER
CONSOLE
Switch between Local/Remote Computer using
Keyboard Hotkey (on Receiver console only)
In addition to using the switching button on the front
panel of the Receiver to switch between the 1
st
and
2
nd
computer, you can also use the keyboard hotkey:
Hotkey sequence = [SCROLL] + [SCROLL] + (y)
(y) = ,
(y) = , Local (2
nd
computer)
(y) = , Remote (1
st
Computer)
OSD Menu (on Receiver console only)
To invoke the OSD Menu, you should hit the
following keyboard hotkeys:
Hotkey Sequence = [SCROLL] + [SCROLL] +
[SPACE]
The hotkey preceding sequence default is SCROLL
+ SCROLL.
For users who want to use a different preceding
hotkey sequence can go to the OSD Menu and
choose any one of the 4 following hotkeys – CAPS,
SCROLL, F12 or NUM.
Each keystroke within a hotkey sequence should be
pressed within 2 seconds. Otherwise, the hotkey
sequence will not be validated.
Buzzer Sound ON/OFF
To turn ON/OFF the buzzer sound on the Receiver,
hit the following hotkey commands:
Hotkey sequence = [SCROLL] + [SCROLL] + B
HOTKEYS AVAILABLE ON THE TRANSMITTER
CONSOLE
Change the Remote Console ON/OFF/View Only
mode (on Transmitter console only)
While you are at the Transmitter Console, you can
turn Remote Console On/Off or make it View Only
by the following:
Hotkey sequence = [SCROLL] + [SCROLL] + M +
(y)
(y) = 1, 2, 3
(y) = 1, Full access (keyboard, mouse and
video)
(y) = 2, Access Denied (no keyboard or
mouse control and blank screen)
(y) = 3, View Only (only video with no mouse
or keyboard control)
When the remote console is turned OFF, the video
screen will become blank and the keyboard and
mouse will be disabled. This provides a security
measure to block or grant access on the remote
console.
When the remote console is in View Only Mode, the
user can only see the screen while access to
keyboard and mouse control are not available.
Audio ON/OFF
To turn ON/OFF the Audio on the TX console, hit the
following hotkey commands:
Hotkey sequence = [SCROLL] + [SCROLL] + A +
(y)
(y) = 0, 1
(y) = 0, Audio OFF
(y) = 1, Audio ON
EDID Emulation Data Select
To select the EDID configuration data set to be used
on the TX unit, (you can copy from either the RX
monitor or TX monitor), just hit the following hotkey
commands:
Hotkey sequence = [SCROLL] + [SCROLL] + D +
(y)
(y) = 1, 2
(y) = 1, Set to EDID data set from RX monitor
(y) = 2, Set to EDID data set from TX monitor
Buzzer Sound ON/OFF
To turn ON/OFF the buzzer sound on the
Transmitter, just hit the following hotkey commands:
Hotkey sequence = [SCROLL] + [SCROLL] + B
Microphone Usage on RX and TX console
If you have used a microphone on the RX console,
note that the microphone input on the RX console
will always be directed to the computer connected on
the TX end. That simply means that if another
person happens to use a recording application on
the TX end, he will pick up sound stream not only