Specifications

44 Operations
Installation and Operations Manual
Administrative Command Summary (continued…)
Set Option Strong Passwords Enables or disables strong password requirements
Set Option Tempscale Sets the Environmental Monitor temperature scale
Set Option Web Timeout Sets the web session (Web Interface) timeout period
Set Port Name Specifies a descriptive field for a serial/Pass-Thru port
Set Port DSR Check Sets the DSR active signal checking for a serial/Pass-Thru port
Set Port Speed Set the connection speed for all serial/Pass-Thru ports
Set Port Timeout Sets the inactivity timer for Pass-Thru sessions
Set SNMP IP Restrict Allows SNMP Get and Set requests only from defined trap destinations
Set SNTP Sets the IP address or hostname of the SNTP servers
Set SNTP DST Enables or disables Daylight Savings Time (DST)
Set SNTP DST End Specifies the settings for DST day/time end parameters
Set SNTP DST Start Specifies the settings for DST day/time start parameters
Set SNTP GMTOffset Sets the local GMT offset applied to the SNTP date/time
Set Subnet Sets the subnet mask of the PT22
Set System Area Specifies to total system area for the system
Set System Area Unit Specifies the system area (footprint) unit of measure
Set System Balance Sets the percent load out-of-balance threshold for 3-phase systems
Set System PF Sets the power factor used in the total system power calculation
Set Telnet Enables or disables Telnet access
Set Telnet Port Sets the Telnet server port number
Set Tower 3Phase Specifies the AC voltage type for the tower
Set Tower Model Specifies the model number for the tower
Set Tower Name Specifies a descriptive field for the PT22
Set Tower ProdSN Specifies the serial number for the tower
Set Tower Specifies the AC or DC voltage type for the tower
Set User Access Sets the access level for a user
Set User Envmon Grants or removes privileges to view input/environmental monitoring status
Set User Password Changes the password for a user
Set UPS AddInfeed Adds an infeed association to a UPS
Set UPS DelInfeed Deletes an infeed association from a UPS
Set UPS GETComm Sets the UPS ‘get’ community string
Set UPS Host Sets the UPS Host IP address or hostname
Set UPS Port Specifies the target port for a UPS
Set UPS Type Sets the UPS type
Set UPS VPoll Enables or disables UPS voltage polling
Show EnergyWise Displays Cisco EnergyWise network configuration information
Show FTP Displays FTP configuration information
Show Infeeds Displays infeed configuration information
Show Network Displays network configuration information for all IPv4 and IPv6 settings
Show Options Displays system option information
Show Ports Displays serial/Pass-Thru port configuration information
Show SNTP Displays SNTP configuration information
Show System Displays system configuration information
Show Towers Displays tower configuration information
Show UPS Displays UPS configuration information
System Status Displays system status configuration information
Version Displays the firmware version