Datasheet
Intel
®
Server Board S5000PAL/S5000XAL TPS Appendix B: BMC Sensor Tables
Revision 2.0
Intel order number: D31979-011
89
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event/Read
ing Type
Event Offset
Triggers
Criticality Assert/De-as
sert
Readable
Value/Offset
s
Event Data Rearm Standby
Disabled Degraded
Sparing OK
Memory A
Error
ECh All Memory
0Ch
Sensor
Specific
6Fh
Correctable
ECC
Uncorrectable
ECC
OK As – Trig Offset A –
Memory B
Error
EDh System-
specific
Memory
0Ch
Sensor
Specific
6Fh
Correctable
ECC
Uncorrectable
ECC
OK As – Trig Offset A –
Memory C
Error
EEh System-
specific
Memory
0Ch
Sensor
Specific
6Fh
Correctable
ECC
Uncorrectable
ECC
OK As – Trig Offset A –
Memory D
Error
EFh System-
specific
Memory
0Ch
Sensor
Specific
6Fh
Correctable
ECC
Uncorrectable
ECC
OK As – Trig Offset A –
B0 DIMM
Sparing
Enabled
F0h All Entity
Presence
25h
Sensor
Specific
6Fh
Entity present OK As – Trig Offset A –
Fully redundant OK
Non-red: suff
res from redund
Non-red: suff
res from insuff
res
Degraded
B0 DIMM
Sparing
Redun-
dancy
F1h All Memory
0Ch
Discrete
0Bh
Non-red: Insuff
res
Critical
As – Trig Offset A –
B1 DIMM
Sparing
Enabled
F2h All Entity
Presence
25h
Sensor
Specific
6Fh
Entity present OK As – Trig Offset A –
B1 DIMM F3h All Memory Discrete Fully redundant OK As – Trig Offset A –