Datasheet

Appendix B: BMC Sensor Tables Intel
®
Server Board S5000PAL/S5000XAL TPS
Revision 2.0
Intel order number: D31979-011
78
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event/Read
ing Type
Event Offset
Triggers
Criticality Assert/De-as
sert
Readable
Value/Offset
s
Event Data Rearm Standby
Watchdog 03h All Watchdog 2
23h
Sensor
Specific
6Fh
Timer expired,
status only
Hard reset
Power down
Power cycle
Timer interrupt
OK As Trig Offset A X
Platform
Security
Violation
04h All Platform
Security
Violation
Attempt
06h
Sensor
Specific
6Fh
Secure mode
violation
attempt
Out-of-band
access
password
violation
OK As Trig Offset A X
Physical
Security
05h Chassis
Intrusion
is chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
Chassis
intrusion
LAN leash lost
1
OK As and De Trig Offset A X
FP Diag
Interrupt
(NMI)
07h All Critical
Interrupt
13h
Sensor
Specific
6Fh
Front panel
NMI/diagnostic
interrupt
Bus
uncorrectable
error
OK As Trig Offset A
System
Event Log
09h All Event
Logging
Disabled
10h
Sensor
Specific
6Fh
Log area
reset/cleared
OK As Trig Offset A X
Session
Audit
0Ah All Session Audit
2Ah
Sensor
Specific
6Fh
00h – Session
activation
01h – Session
deactivation
OK As As defined
by IPMI
A X