Datasheet
Intel
®
Server Board S5000PAL/S5000XAL TPS Jumper Block Settings
Revision 2.0
Intel order number: D31979-011
51
7. Open the server and move the jumper from the “enabled” position (pins 2-3) to the
“disabled” position (pins 1-2).
8. Close the server system and reconnect AC power and power up the server.
Note: Normal BMC functionality is disabled with the force BMC update jumper set to the
“enabled” position. The server should never be run with the BMC force update jumper set in this
position and should only be used when the standard firmware update process fails. This jumper
should remain in the default – disabled position when the server is running normally.
6.2 BIOS Select Jumper
The jumper block at J3H1, located just to the left of the SSI control panel header, is used to
select which BIOS image the system will boot to. Pin 1 on the jumper is identified with a ‘▼’.
This jumper should only be moved if you wish to force the BIOS to boot to the secondary bank
which may hold a different version of BIOS.
TP02305
J3H1
23 23
1-2: Force BIOS
to bank 0
2-3: System is
configured for
normal operation
(factory default)
Pins What happens at system reset…
1-2 Force BIOS to a alternative bank
2-3
System is configured for normal operation (Default)
Figure 19. BIOS Select Jumper (J3H1)
BIOS update is supported when the Recovery Jumper is either set on pins 1-2 (recovery mode),
or pins 2-3 (normal mode).
To perform a normal BIOS update, follow the below steps:
1. Boot the system with the jumper covering pins 2 and 3.
2. Update the BIOS using iFlash or the Intel
®
One Flash Update (OFU) utility.
3. Reset the system.
4. The system will boot from the new BIOS.
If the system can not boot, perform the below steps to recover:
1. Boot the system with the jumper covering pins 1 and 2.
2. Update the BIOS using iFlash or the Intel
®
One Flash Update (OFU) utility.