7.2 Digital Outputs
Error: Monitoring Output
Whenever a system failure occurs (i.e. overtemperature), the Error output responds (LO
position), and the green LED on the front panel is switch to red. The drive output stage is
switched off and the error will not reset until the user resets the drive by switching the
enable input. If the error occurs again the problem still exists.
The output is an open-collector output and via an external pull-up resistor adaptable to the
most industrial logics, up to +30 V.
Additional information about the schematic refer chapter 3.2.
Range of Output Voltage min. 0.4 V at LO – max. 30 V at HI
Output Impedance >100 Ohm at LO
Permanent Output Current 20 mA max.
Note:
The logical state of this output is clearly visible by the green/red OK/Fault LED on
the front panel.
Ready: Monitoring Output
The Ready output is set if there no errors occurs in the drive (LO position). On error the
output is opened and will not reset until the user resets the drive by switching the enable
input. This output is a mirror image of the Error output.
The output is an open-collector output and via an external pull-up resistor adaptable to the
most industrial logics, up to +30 V.
Additional information about the schematic refer chapter 3.2.
Range of Output Voltage min. 0.4 V at LO – max. 30 V at HI
Output Impedance >100 Ohm at LO
Permanent Output Current 20 mA max.
Note:
The logical state of this output is clearly visible by the green/red OK/Fault LED on
the front panel.