User manual

User Manual SCA-SS-70-10
5.3 Jumpers
J1 J2 J3 J6 J7 J8 J9 Function Mode
Set Open Open Open Open Open Set Speed Control by Voltage
Set Open Open Set Open Open Set Speed Control by IxR
Open Open Open Open Set Open Open Torque Control
Open Open Set Open Open Open Set Speed Control by Tacho
Open Set Open Open Open Open Set Speed Control by Encoder
Open Open Set Open Open Set Open Analog Position
J10 J11 Select range of the Current
Open Open Current range is from 3 A to 7 A.
Open Set Current range is from 0 A to 5 A.
Set Open Current range is from 5 A to 10 A.
Set Set Current range is from 0 A to 10 A.
ElectroCraft
®
E-Mail: info@electrocraft.com www.electrocraft.com May 2009
27
J4 J5 Methods of entering the set value
Open Set External selection using a voltage between XC/18 and XC/19.
Set Open The internal Offset potentiometer is used.