Specifications
Adjustments to be made regularly
Adjustment of the MIN and MAX value
The
MIN
and
MAX
value
is
the
lowest
r
espectively
highest
value
that
is
allowed
for
the
supply
line
temperature.
Adjusting
the
minimum
and
maximum
supply
line
temperatur
e
is
par
ticularly
important
if
your
home
has
floor
heating.
If
your
house
has
floor
heating
and
par
quet
floor
,
the
supply
line
temperatur
e
should
not
be
higher
than
45°C.
Else
the
floor
might
get
damaged.
If
you
have
floor
coils
and
stone
tiles,
the
MIN
value
should
be
22-25°C
in
summer
when
no
heating
is
r
equired
–
to
obtain
a
comfor
table
floor
temperature.
If
ther
e
is
a
basement
to
your
house,
the
MIN
value
should
be
adjusted
to
a
suitable
temperatur
e
in
summer
too,
to
avoid
a
humid
and
chilly
basement.
In
such
cases,
the
value
for
HEA
T
STOP
needs
being
adjusted
upwar
ds.
If
you
wish
to
change
the
MIN
or
MAX
value:
1
Open
the
main
menu
INFORMA
TION
by
pr
essing
the
right-
or
left-hand
button once.
Y
ou
will
find
the
cursor
at
the
sub-menu
OPERA
TION
2
Pr
ess
the
”down”
button
to
move
the
cursor
to
the
sub-menu
HEA
T
CURVE
3
Open
the
selected
menu
by
pr
essing
the
right-hand
button
once.
Y
ou
will
find
the
cursor
at
the
parameter
CURVE.
4
Pr
ess
the
”down”
button
to
move
the
cursor
to
MIN.
5
Open
the
selected
parameter
by
pr
essing
the
right-hand
button
once.
The
cursor
is
at
MIN
6
Raise
or
lower
the
value,
using
the
”up”
and
”down”
button
r
espectively
.
7
Pr
ess
the
left-hand
button
thr
ee
times
to
r
eturn
to
the
main
menu.
R
e
p
e
a
t
t
h
e
p
r
o
c
e
d
u
r
e
t
o
c
h
a
n
g
e
t
h
e
M
A
X
va
l
u
e
,
r
e
p
l
a
c
i
n
g
M
I
N
b
y
M
A
X
a
t
s
t
e
p
4.
Control35
Adjustment of the HEAT STOP value
The
HEA
T
STOP
function
stops
all
pr
oduction
av
radiator
heat
when
the
outside
air
temperatur
e
is
equal
to
or
higher
than
the
value
enter
ed
for
heat
stop.
When
the
heat
stop
function
is
activated,
the
cir
culation
pump
will
be
turned
of
f
except
when
warm
water
is
being
pr
oduced.
Even
if
shut
of
f,
the
pump
will
be
”exercised”
during
1
minute
a
day
.
Factory
setting
for
heat
stop
is
17°C.( 0~ 24°C adjustable )
If
you
wish
to
change
the
HEA
T
STOP
value:
1
Open
the
main
menu
INFORMA
TION
by
pr
essing
the
right-
or
left-hand
button once.
Y
ou
will
find
the
cursor
at
the
sub-menu
OPERA
TION
2
Pr
ess
the
”down”
button
to
move
the
cursor
to
the
sub-menu
HEA
T
CURVE
3
Open
the
selected
menu
by
pr
essing
the
right-hand
button
once.
4
Y
ou
will
find
the
cursor
at
the
parameter
CURVE.
5
Pr
ess
the
”down”
button
to
move
the
cursor
to
HEA
T
STOP
6
Open
the
selected
parameter
by
pr
essing
the
right-hand
button
once.
The
cursor
moves
to
HEA
T
STOP
7
Raise
or
lower
the
value,
using
r
espectively
the
”up”
or
”down”
button.
8
Pr
ess
the
left-hand
button
thr
ee
times
to
r
eturn
to
the
main
menu.