Specifications
Control 38
Alarm Messages
In
the
event
of
an
alarm
message,
try
to
r
e-star
t
the
unit
with
the
safety
switch.
If
this
does
not
work,
try
to
solve
the
pr
oblem
with
the
help
of
the
table
below
.
Call
your
installation
contractor
if
you
need
help.
T
able
:
Alarm
Messages
The
following
table
only
applies
to
installations
using
gr
ound
water
as
brine
system
liquid.
Message
Signification
Cause
Action
BRINE
OUT
T
emperatur
e
of
brine
leaving heat
pump
is
lower
than
setpoint
value.
Compr
essor
is
stopped
and
no
warm
water
is
pr
oduced.
The
minimum
Brine
sytem
temperatur
e
has been
r
eached
The
system
r
esets
automatically
when
temp.
has
risen
to
setpoint
value
BRINEFLOW LOW
Flow
switch
not
active
at
latest
compr
essor
star
t.
Compr
essor
is
stopped
and
no
warm
water
is
pr
oduced.
Brine
sytem
flow
is
too
low
.
Call
installation
contractor
Message
Signification
Cause
Action
RETURN TEMP
Return line temperature sensor error; All
operation stopped, except circulation pump of
heating system
.
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .
FEED IN TEMP
Supply line temperature sensor error; All
operation stopped, except circulation pump of
heating system
.
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .
BRINE OUT TEMP
Brine out temperature sensor error /
Defrost temperature sensor error ( for air
source heat pump ) .
Sensor disconnected;
Sensor defective.`
Check the connections,the wire,
or change it .
OUTDOOR TEMP
Outside air temperature sensor error;
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .
ROOM TEMP
Room air temperature sensor error;
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .
WARM WATER
TEMP
Water tank temperature sensor error;
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .
HIGH PRESS
All operation stopped; High pressure switch cut
out; compressor is stopped; No warm water is
produced
The wire disconnectted;
Refrigerance leakage, lack of refrigerance;
water flow stop in the room cycle.
Check the wire connection;
Refrigerance recharge;
Check the water cycled pump for the room
heating system;
Or
call
your
installation
contractor
.
LOW PRESS
All operation stopped; Low pressure switch cut
out; compressor is stopped; No warm water is
produced
The wire disconnectted;
No refrigerance (leakage out );
Pipe was plugged.
Check the wire connection;
Refrigerance recharge;
Check the pipe system;
Or
call
your
installation
contractor
.
CMP OVER
All operation stopped;
Compressor overload protection
The actual current over the contactor ‘s
allowed current.Compressor current too
large;or the AC contactor current adjust too
small.(6K,8K should be adjust to 11A;
10K,12K should be adjust to 14A;
16K,20K,25K,should be adjust to 16A)
Check the compressor;
Adjust the AC contactor’s current range;
Or call
your
installation
contractor
.
ADD HEAT OVER
All operation stopped;
Electrical heater overheat .
The temperature of electrical heater over the
max allowed temperature.
Water flow too low or stoped.
Check the water cycled pump for the room
heating system;
Or call
your
installation
contractor
.
WTPUMP OVER
All operation stopped;
Water pump overheat .
The temperature of the water pump (room
heating cycle ) over the max allowed
temperature.No water in the cycle system.
Check the water cycled pump for the room
heating system;
Or call
your
installation
contractor
.
CMP AIR OVER
All operation stopped;
Compressor exhaust overheat .
Lack of refrigerance.
Refrigerance recharge;
Or
call
your
installation
contractor
.
POWER SUPPLY
Phase error;
For three-phase, the phase
or
der
r
eversed or
wrongly connected.
For single-phase, the “ three-phase option
port ” in the circuit board is not connected or
loose.
Check the connections,the wires.
Or Call
your
installation
contractor
CMP TEMP
Compressor exhaust temperature sensor error;
Sensor disconnected;
Sensor defective.
Check the connections,the wire,
or change it .