User manual

4
T
r
ouble
shooting
4.1
Alarm
Messages
In
the
event
of
an
alarm
message,
try
to
r
e-star
t
the
unit
with
the
safety
switch.
If
this
does
not
work,
try
to
solve
the
pr
oblem
with
the
help
of
the
table
below
.
Call
your
installation
contractor
if
you
need
help.
See
”Refer
ences”
on
page
30.
T
able
3:
Alarm
Messages
28
Error code Explanation Cause How to do
RETURN TEMP
Return water
temperature
sensor
error;
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
FEEDLINE TEMP
Supply
water
temperature
sensor
error;
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
PIPE
TEMP
Defrost
temperature
sensor (on evaporator)
error
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
OUTDOOR
TEMP
Outside
air
temperature
sensor
error
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
ROOM
TEMP
Room
air
temperature
sensor
error;
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
CMP
TEMP
Compressor
exhaust
temperature
sensor
error;
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 50K
WARM
WATER TEMP
Water
tank
temperature
sensor
error
Sensor
disconnected; Sensor
was
defective.
Check
the
connections, the
wire of sensor, or
change
the sensor.
Under 25
°C
, the resistance of sensor should be 5K
HIGH
PRESS (single
compressor system)
COMP.A PRESS(double
compressor system)
Compressor high
pressure protection
The
wire
disconnected;
lack
of
refrigerant;
water
flow
stop
in
the
room
cycle
Check
the
wire
connection; check refrigerant
quantity; Check
the
water
cycled
pump
for
the
room heating
system;
Check if the
water system contains air
LOW
PRESS (single
compressor system)
COMP.B PRESS(double
compressor system)
Compressor low
pressure protection
The
wire
disconnected;
lack
of
refrigerant;
Check
the
wire
connection; check refrigerant
quantity;
CMP
OVER
Compressor overload
The
actual
current
over
the
contactor
‘s
allowed
current.
Compressor
current
too large;
Check
the
wire
connection;
Check if the water system contains air, and cause the water
temperature over high and current over large
ADD
HEAT
OVER OR FLOW
TROUBLE
Supplementary
electrical heater over
heat or water flow got
problem
The
temperature
of
electrical
heater
over
the max
allowed
temperature.
Water
flow
too
small
or
stopped.
Check
the
wire
connection;
Check if the water system contains air or without water
CMP
AIR
OVER
Compressor exhaust air
temperature over heat
Water flow too small;
Lack of refrigerant
Check if the water system contains air or without water
Check the refrigerant quantity
WARMWATER
TEMP TOO
LOW
Temperature
of
the
water
tank
is
too
low.
Water
tank
temperature
less
than
10
ć
A . During heat pump running, whatever mode heat pump runs,
heat pump will give an alarm with sound, at the time, heat pump will
automatically turn to water tank heating, and
then go back to previous running mode until water tank’s
temperature get to 20
ć
B . During heat pump is not running, heat pump will give an alarm
with sound: WARM WATER. TOO LOW
POWER
SUPPLY
Phase error
For
three-phase,
the
phase
or
der
r
eversed
or wrongly
connected.
For
single-phase,
the
three-phase
option
Port
in
the
circuit
board
is
not
connected
or loose.
Please check if the phase connections were correct.