User manual
3.2.6
Adjustment
of
the
HIGH T STOP and LOW T STOP
The
HIGH T STOP and LOW T STOP
function
stops water production to room floor
when
the
outside
air
temperatur
e
is
equal
to
higher or lower
than
the
value
enter
ed
for
HIGH T STOP or LOW T STOP.
When
the
function
is
activated,
the
cir
culation
pump
will
be
turned
of
f. The factory setting of the HIGH T STOP is 50°C.( 0 ~ 50 °C adjustable )
If
you
wish
to
change
the
HIGH T STOP OR LOW T STOP
value:
1
Open
the
main
menu
INFORMA
TION
by
pr
essing
the
right-
or
left-hand
button once.
Y
ou
will
find
the
cursor
at
the
sub-menu
OPERA
TION
2
Pr
ess
the
”down”
button
to
move
the
cursor
to
the
sub-menu
HEA
T
CURVE
3
Open
the
selected
menu
by
pr
essing
the
right-hand
button
once.
4
Y
ou
will
find
the
cursor
at
the
parameter
CURVE.
5
Pr
ess
the
”down”
button
to
move
the
cursor
to
HIGH T STOP or LOW T STOP.
6
Open
the
selected
parameter
by
pr
essing
the
right-hand
button
once.
The
cursor
moves
to
7
Raise
or
lower
the
value,
using
r
espectively
the
”up”
or
”down”
button.
8
Pr
ess
the
left-hand
button
thr
ee
times
to
r
eturn
to
the
main
menu.
3.2.7
Graph
of
r
ecent
changes
in
TEMPERA
TURE
All
temperatur
es
r
egister
ed
during
the
last
hour
can
be
viewed
in
the
sub-menu
TEMPERA
TURE
in
the
shape
of
a
graph.
This
will
enable
you
to
monitor
changes
in
the
dif
fer
ent
system
temperatures
.
There
is
a
graph
available
for
all
temperatures,
except
for
the
OUT / ROOM
temperature,
wher
e
you
can
only
view
the
measured
value.
The
integral
value
that
is
displayed
r
epr
esents
the
heating
system’s
ener
gy
balance.
If
you
wish
to
check
the
TEMPERA
TURE
graphs:
1
Open
the
main
menu
INFORMA
TION
by
pr
essing
the
right-
or
left-hand
button once.
Y
ou
will
find
the
cursor
at
the
sub-menu
OPERA
TION.
25
C
30
-16
0
16
32
48
64
60
48
FEEDLINE
2
Pr
ess
the
”down”
button
to
move
the
cursor
to
the
sub-menu
TEMPERA
TURE
3
Open
the
menu
by
pr
essing
the
right-hand
button
once.
4
Y
ou
will
find
the
cursor
at
the
parameter
OUT
.
5
P
r
e
ss
t
h
e
”
do
w
n
”
o
r
”
u
p
”
b
u
tt
o
n
t
o
mo
v
e
t
h
e
c
u
r
so
r
t
o
t
h
e
d
e
s
i
r
e
d
t
e
mp
e
r
a
t
u
r
e
.
6
Open
the
selected
value
by
pr
essing
the
right-hand
button
once.
A
graph
will
be
shown
in
the
display
.
7
Move
the
cursor
along
the
time
axis
using
the
”up”
(plus)
or
the
”down”
(minus)
button.
T
h
e
ex
a
c
t
t
e
mp
e
r
a
t
u
r
e
a
t
t
h
e
s
e
l
e
c
t
e
d
po
i
n
t
o
f
t
i
m
e
a
pp
e
a
r
s
a
t
t
h
e
t
op
o
f
t
h
e
d
i
sp
l
a
y
.
8
Pr
ess
the
left-hand
button
thr
ee
times
to
r
eturn
to
the
main
menu.
The factory setting of the LOW T STOP is -50°C.( -50 ~ 0 °C adjustable ) .
HIGH T STOP
or LOW T STOP.
‘HIGH T STOP’ and ‘LOW T STOP’ functions are only for room heating, the water tank
normally when the two functions are active.
heating still works