User manual
15
3.1.2.6
Sub-Menu
OPERA
TING
TIME
3.1.2.8
Sub-Menu
MAN TEST
3.1.2.7
Sub-Menu
RESET
Reset to factory setting value. Press the right button for 5 seconds.
The Sub-Menu MAN TEST contains ADD1 / ADD2 / ADD3 / HEAT PUMP / 3 WAY
4 WAY / WARM PUMP / OUT FAN; You can choose ON / OFF to control the each part for testing.
How to enter the Sub-Menu MAN TEST:
You need to choose the " MAN TEST" on the main menu ( INFORMATION)
And press the right button for 3 seconds .
Menu
T
ext Descri
p
tion Ad
j
ustable b
y
HEATPUMP Total operating hours of heat pump since installation.
Operatin
g
time will not be reset to ze
r
o.
(3kW) since installation. Operating time will
ADD1 Total operating hours of auxiliary heater
ADD2
ADD3
will not be reset to ze
r
o.
(6kW) since installation. Operating time will
Total operating hours of auxiliary heater
will not be reset to ze
r
o.
(9kW) since installation. Operating time will
Total operating hours of auxiliary heater
will not be reset to ze
r
o.
can not
can not
can not
can not
OPERATION TIME
HEATPUMP
ADD 1
0
H
0
H
ADD 2
0
H
ADD 3
0
H
ADD 1
3 WAY
4 WAY
WARM PUMP
MAN TEST
OFF
OFF
OFF
OFF
OUT FAN
OFF
ADD 2
OFF
ADD 3
OFF
HEATPUMP
OFF
Notice: when installer to test the components function in submenu ‘MAN TEST’, it recommend that
start the water pump before start the compressor and electrical heater.