User Manual

www.SereneLifeHome.com
9
Dehumidication Mode
When pressing mode key or choosing
dehumidication mode by pressing the
remote controller, the dehumidication
indicator lamp lights up.
Remove the dehumidication water wedge,
insert water manifold, place the other end
of the water manifold into the water vessel
or drainage passage, as shown in the right
gure.
After entering the dehumidication mode,
if room tempearture≥17°C (62°F), the compressor is ON. Then control as
follows: when room temperature ≤15°C (59°F), the compressor is OFF;
when temperature increases to room temperature≥17°C (62°F), the
compressor will start again (in order to protect the compressor, it will be
restarted 3min. later).
In dehumidication mode, the fan is defaulted to run at low speed, and
wind speed cant be adjusted.
Temperature can’t be set.
Auto mode (for cooling model only)
When pressing mode key or choosing auto mode by pressing the remote
controller, the auto indicator lamp lights up.
After choosing Auto mode, operation state is determined by
environmental temperature: when environmental temperature is
higher than 25°C (77°F), the operation state is the same as that of cooling
mode; when environmental temperature is lower than 25°C (77°F), the
operation state is the same as that of fan mode.
Timer Mode
In standby state, press the Timer key to set ON time. Press Up and Down
keys to set ON time (1~24H), and the timer indicator lamp lights up.
In ON state, pressure the timer key to set OFF time. Press Up and Down
keys to set OFF time (1~24H), and the timer indicator lamp lights up.
Clean and Maintenance
DRAINAGE METHOD
This product is equipped with automatic water vaporization system.
The condenser is cooled with the circulating of condensing water, so as
to improve cooling eciency and save energy.