User Manual
39
Tempest Operation Manual
Envelopes
Free-Running LFOs
By default, the wave cycles of Tempest’s two low frequency oscillators are
restarted by a note on, beat, or play command. However, you can set the LFOs
to be free running so that once triggered, the wave cycle continues without being
restarted.
To disable wavecycle restart for LFO 1 or LFO 2:
1. In the SCReenS section, press the SoundS button.
2. In the
lfo 1&2 section, press the lfo2 button on or off to display the
parameters for the LFO that you want to edit.
3. Press the Page Right (right arrow) soft button to display the
ReStaRt param-
eter for the LFO’s wave cycle.
4. Turn soft knob 4 (
ReStaRt) and set the chosen LFO’s wave cycle to off.
(Conversely, choosing note, Beat, or Play causes the LFO’s wave cycle to
restart each time it receives the selected trigger.)
To use free-running LFO’s you must assign a sound to a voice. To do this,
press the 16 sounds button, then press the sounds button in the Screens section.
Next, tap a pad to select the sound you want to assign to a voice. Finally, press the
Mod Paths button in the LFO section, then press the Page Down button once. Turn
soft knob 3 to assign the voice.