Sequencer
Play Mode: Normal, Step, Play Once—(In the seq tab in the display)
Selects how the sequencer reacts when triggered. In normal mode, when
the sequencer is triggered, the sequence will play continuously until
manually stopped. In Step mode, the sequencer will advance step-by-step
with each new trigger it receives. In play once mode, the sequencer will
play the sequence through, one time only, when triggered.
Restart: Off, On—(In the seq tab in the display) Selects whether or not
the sequence restarts from step 1 each time a trigger is received from any
of the various gate sources (keyboard, external input, gate in, etc.).
Env Trig/Step:
Off, On—(In the seq tab in the display) Selects whether or
not the envelopes are triggered by each step of the sequence. If set to Off,
the envelopes are triggered only by the initial sequence trigger.
Length: 16x16, 8x32—(In the seq misc tab in the display) Selects the
maximum length of the sequence.