User Manual

77
OB-6 Operation Manual
Appendix C: MIDI Implementation
Received NRPN Messages
Status Second Third Description
1011 nnnn 0110 0011 0vvvvvvv NRPN parameter number MSB CC
1011 nnnn 0110 0010 0vvvvvvv NRPN parameter number LSB CC
1011 nnnn 0000 0110 0vvvvvvv NRPN parameter value MSB CC
1011 nnnn 0010 0110 0vvvvvvv NRPN parameter value LSB CC
1011 nnnn 0110 0000 0xxxxxxx NRPN parameter value Increment
1011 nnnn 0110 0001 0xxxxxxx NRPN parameter value Decrement
1011 nnnn 0010 0101 0111111 RPN parameter number MSB CC - Reset NRPN param-
eter number (when both MSB and LSB received)
1011 nnnn 0010 0100 0111111 RPN parameter number LSB CC - Reset NRPN param-
eter number (when both MSB and LSB received)
Global Parameter Data
The table shows the Global data sent and received on global parameter
dumps, and corresponding NRPN number when sent/received individually.
NRPN Range Description
1024 0-100 Master Fine Tune
1025 0-24 Master Coarse Tune
1026 0-16 MIDI Channel
0 = All
1027 0-3 MIDI Clock Mode
0 = Off
1 = Master
2 = Slave
3 = Slave Thru
1028 0-1 MIDI Clock Port
0 = MIDI Port
1 = USB
1029 0-2 MIDI Param Send*
0 = NRPN
1 = CC
2= Off
1030 0-2 MIDI Param Receive†
0 = NRPN
1 = CC
2= Off
1031 0-1 MIDI Control Enable
0 = Off
1 = On
1032 0-1 MIDI SysEx Enable
0 = Off
1 = On
NRPN Range Description
1033 0-3 MIDI Out Select
0 = Off
1 = MIDI
2 = USB
3 = MIDI+USB
1035 0-1 Local Control*
0 = Off
1 = On
1037 0-2 Pot Mode
0 = Relative
1= PassThru
2 = Jump
1039 0-3 Seq Jack
0 = normal
1= trigger
2= gate
3= trigger+gate
1040 0-3
Sustain Polarity
0 = normally open
1= normally closed
2= Sustain Normally Open/
Sequencer Normally Closed
3= Sustain Normally Closed/
Sequencer Normally Open
1041 0-3 Velocity Response
1042 0-3 Aftertouch Response
1043 0-1 Mono/Stereo
0 = Stereo
1 = Mono
1044 0-16 Alt Tuning
*Controller received, but not transmitted.
†Controller transmitted, but ignored when received.