Use & Care Guide
SPECIFICATIONS:
These panels are manufactured by a continuous laminating process in lengths as required.
Composition:
1. Reinforcement: random chopped fiberglass roving.
2. Resin mix: modified polyester copolymer and inorganic fillers and pigments.
Finished Panel Quality:
1. Panels shall have a wear side with a pebble-like embossed finish. Color shall be uniform throughout, as specified.
The backside shall be smooth. Backside imperfections which do not affect functional properties are not cause for
rejection.
2. Physical properties shall be as set forth in Table 1.
3. Product quality standards and tolerances for panel weight and thickness shall be as set forth in Kemlite
Company’s Quality Control Procedures/Standards which are available on request.
4. Dimensions shall be as specified on purchase order, subject to the following tolerances:
Width: ±1/8" (3.2 mm)
Length: ±1/8" (3.2 mm) up to 12' (3.7 m)
Squareness: not more than 1/8" (3.2 mm) out of square
5. Panels shall be installed in accordance with manufacturer’s guidelines as set forth in the Structoglas “Installation
Guide.”
FABRICATING RECOMMENDATIONS:
Note: Protect your eyes with goggles and cover your nose and mouth with a filter mask when cutting Structoglas
panels.
Hand fabrication: Drilling-high speed drill bit (60° cutting angle, with 12°-15° clearance) or hole saw.
Cutting: Sheet metal shears or circular saw with reinforced carborundum or carbide-tipped blade.
Production fabrication: Use carbide-tipped tools. Straight cuts can be sheared (90° cutting edge with 0.002"
(0.05 mm) clearance) or sawed. For irregular cuts, use die punch or band saw.
STORAGE:
All Structoglas products should be stored indoors.
SERVICEABLE TEMPERATURE RANGE:
Panels will perform in temperatures from -40°F (-40°C) to 150°F (66°C). For use in environments beyond this range
contact Kemlite Company for recommendations.
LIMITATIONS:
Near heat source - Structoglas panel products may discolor when installed behind or near any heat source which
radiates temperatures exceeding 130°F (55°C), such as cookers, ovens, and deep fryers.
NOTICE:
Panels will provide a clean, aesthetically-pleasing finished installation. However, by nature, fiberglass reinforced plastic
paneling may occasionally have small areas that are aesthetically unacceptable for use. Panels should be inspected
on-site prior to installation. If any portion of material does not provide an acceptable appearance, Kemlite Company
should be notified at once. Upon verification of unacceptability, that portion of material will be replaced by Kemlite
Company. Kemlite Company’s sole responsibility is for the replacement of defective materials but not for labor or other
handling or installation expenses.
CERTIFICATION:
A. Flame spread ≤ 200, smoke developed ≤ 450
(per ASTM E-84)
B. Meets USDA/FSIS requirements
C. UL Classified
D. Frp does not support mold or mildew (per ASTM D3273
and ASTM D3274)
We believe all information given is accurate. It is offered in good faith,
but without guarantee. Since conditions of use are beyond our control,
all risks are assumed by the user. Nothing herein shall be construed as a
recommendation for uses which infringe on valid patents or as extending a
license under valid patents.
FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS
The numerical flame spread and smoke development ratings are not intended to reflect
hazards presented by Kemlite Company products or any other material under actual
fire conditions. These ratings are determined by small-scale tests conducted by
Underwriters Laboratories and other independent testing facilities using the American
Society for Testing and Materials E-84 test standard (commonly referred to as the
“Tunnel Test”). KEMLITE COMPANY PROVIDES THESE RATINGS FOR MATERIAL
COMPARISON PURPOSES ONLY. Like other organic building materials (e.g. wood),
panels made of fiberglass reinforced plastic resins will burn. When ignited, frp may
produce dense smoke very rapidly. All smoke is toxic. Fire safety requires proper
design of facilities and fire suppression systems, as well as precautions during
construction and occupancy. Local codes, insurance requirements and any special
needs of the product user will determine the correct fire-rated interior finish and fire
suppression system necessary for a specific installation.
1-800-238-6874
1-731-764-2153
1-731-764-6316 fax
www.structoglas.com Sequentia and Structoglas are registered trademarks of Kemlite Company, Inc. Form 2501 Rev. 13 (2168)