User's Manual

A fault condition will occur when the battery is
below 10 percent capacity.
A fault condition will occur if the EXT transceiver is
disconnected from the keypad.
When the user presses any key on an idle keypad, it
will display "please wait" while it retrieves current
status information from the control panel. After 30
seconds with no key presses it will return to standby
mode.
Mounting the EXT in an LCD Keypad
Remove the back plate from the front of the keypad
by pressing on the rear tabs and pulling outward.
Carefully snap the plastic mounts (included with the
EXT) into the mounting holes on the LCD board as
shown in Figure 2.
Install a standoff (included with the EXT) into the top
mounting hole of the EXT. A standoff is provided to
prevent the EXT from touching the LCD board.
Align the EXT with the plastic mounts and header
pins on the LCD. Gently press downward until the
EXT secures on to the plastic mounts and header pins.
Insert two screws into the two lower mounts and
turn to secure the EXT.
Figure 2: Mounting the EXT in an LCD Keypad
Enrolling the EXT
The following instructions provide a guideline for
enrolling the EXT into panel memory.
Verify that all wiring is correct prior to applying
power to the control panel.
Connect the battery leads to the battery.
Connect the AC transformer.
The EXT will automatically scan into the control
system’s memory.
1.
2.
3.
4.
5.
1.
2.
3.
4.
Slide EXT on to header pinsSlide EXT on to header pins
2 holes
for plastic
mounts
2 holes
for plastic
mounts
AntennaAntenna
Troubleshooting
Problem Actio n
The panel does not
respond to wireless
sensors. There are no
alarm, chime, or walk
test responses.
Verify that the EXT is enrolled.
This can be done by checking
option “EXT Module” (60401)
in the “ST - Modules” menu in
programming. If this option is
0, the EXT is not recognized by
the system. Remove the EXT
and see if a trouble occurs. If
not, replace the EXT.
Bring the wireless sensors
closer to the EXT and test
again. If signals are properly
received, the issue may be
related to environmental
noise or interference.
Distance from the receiver
and/or installation
environment will affect
the sensor signal strength.
Reposition the sensor and/or
EXT if necessary.
Host mode EXT does not
funcon.
Verify that the EXT is enrolled.
This can be done by checking
option “EXT Module” (60401)
in the “ST - Modules” menu
in programming. It should
display the address of the
keypad that is supporting the
EXT. Delete and re-enroll the
EXT if you are unsure that the
correct keypad ID is shown.
2